AC/DC Voltage, Frequency, Duty Cycle Measurements

  

CAUTION: 

 Do not measure voltages if a motor on the circuit is being switched ON or OFF. Large 

voltage surges may occur that can damage the meter. 

 

1.  Rotate the function switch to the 

position.  

2. Press 

the 

MODE

 button to select AC or DC Voltage. 

3. 

Insert the black test lead banana plug into the negative 

COM

 jack. 

Insert the red test lead banana plug into the positive 

V

 jack. 

4. 

Touch the black test probe tip to the negative side of the circuit.  
Touch the red test probe tip to the positive side of the circuit. 

5. 

Read the voltage value in the display. 

6. Press 

the 

Hz %

 button to display Frequency 

7. Press 

the 

Hz %

 button to display Duty Cycle 

 
 
 
 
 
 
 
 

Resistance, Diode, Continuity Measurements 

Note: Remove power from the device under test before making resistance measurements 

1.  Set the function switch to the 



position. 

2. 

Insert the black test lead banana plug into the negative 

COM

 jack. 

Insert the red test lead banana plug into the positive 

V

 jack. 

3. 

Touch the black test probe tip to one side of the device.  
Touch the red test probe tip to the other side of the device. 

4. 

Read the resistance value in the display. 

5. Press 

the 

MODE

 button to select the 

DIODE

 mode. The Diode symbol will 

appear in the display. 

6. Press 

the 

MODE

 button to select the 

Continuity

 mode. The continuity symbol 

will appear in the display. If the resistance is <150 ohms the tone will sound. 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MA410T

Страница 1: ...User Guide 400Amp True RMS AC Clamp Meter NCV Model MA410T www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...ndicates a potentially hazardous situation which if not avoided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY...

Страница 3: ...r fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when making measurements if the vo...

Страница 4: ...t rear 13 Positive input jack Display icons Description HOLD Data Hold AUTO Autoranging DC Direct Current AC Alternating Current Low battery REL Relative V Volts Voltage Ohms Resistance A Amperes Curr...

Страница 5: ...light NOTE The conductors in electrical cord sets are often twisted For best results move the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor NO...

Страница 6: ...lay Frequency 7 Press the Hz button to display Duty Cycle Resistance Diode Continuity Measurements Note Remove power from the device under test before making resistance measurements 1 Set the function...

Страница 7: ...o freeze the LCD reading press the HOLD button The HOLD icon appears on the LCD Press the HOLD button again to return to normal operation Relative Press the REL button REL will appear in the display t...

Страница 8: ...ry and store it separately Battery Replacement 1 Remove the 2 Phillips head screws that secure the rear battery cover 2 Open the battery compartment 3 Replace the 2 AAA 1 5V batteries 4 Secure the bat...

Страница 9: ...DC Voltage 600 VDC 1V 2 0 2 digits 400 0 0 1 1 0 4 digits 4 000k 0 001k 40 00k 0 01k 400 0k 0 1k 1 5 2 digits 4 000M 0 001M 2 5 3 digits Resistance 40 00M 0 01M 3 5 5 digits 40 00nF 0 01nF 4 0 20 digi...

Страница 10: ...emperature 20 C to 60 C 4 F to 140 F Operating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 2000meters 7000ft maximum Battery Two AAA...