MA410T-EU-EN-V1.0-7/12 

SAFETY NOTES 

  Do not exceed the maximum allowable input range of any function. 

  Do not apply voltage to meter when resistance function is selected. 

  Set the function switch OFF when the meter is not in use. 

  Remove the battery if meter is to be stored for longer than 60 days.

 

WARNINGS 

  Set function switch to the appropriate position before measuring. 

  When measuring volts do not switch to current/resistance modes. 

  Do not measure current on a circuit whose voltage exceeds 600V. 

  When changing ranges always disconnect the test leads from the circuit under test. 

CAUTIONS 

  Improper use of this meter can cause damage, shock, injury or death. Read and understand 

this user manual before operating the meter. 

  Always remove the test leads before replacing the battery or fuses. 

  Inspect the condition of the test leads and the meter itself for any damage before operating the 

meter. Repair or replace any damage before use. 

  Use great care when making measurements if the voltages are greater than 25VAC rms or 

35VDC. These voltages are considered a shock hazard. 

  Always discharge capacitors and remove power from the device under test before performing 

Diode, Resistance or Continuity tests. 

  Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty 

of connection to the recessed electrical contacts. Other means should be used to ensure that 
the terminals are not "live". 

  If the equipment is used in a manner not specified by the manufacturer, the protection provided 

by the equipment may be impaired. 

 

Function Maximum 

Input 

A AC,  

400A 

V DC, V AC 

600V DC/AC 

Resistance, Capacitance, Frequency, Diode 
Test, Continuity, Temperature 

250V DC/AC 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MA410T

Страница 1: ...User Guide 400Amp True RMS AC Clamp Meter NCV Model MA410T www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...ndicates a potentially hazardous situation which if not avoided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY...

Страница 3: ...r fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when making measurements if the vo...

Страница 4: ...t rear 13 Positive input jack Display icons Description HOLD Data Hold AUTO Autoranging DC Direct Current AC Alternating Current Low battery REL Relative V Volts Voltage Ohms Resistance A Amperes Curr...

Страница 5: ...light NOTE The conductors in electrical cord sets are often twisted For best results move the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor NO...

Страница 6: ...lay Frequency 7 Press the Hz button to display Duty Cycle Resistance Diode Continuity Measurements Note Remove power from the device under test before making resistance measurements 1 Set the function...

Страница 7: ...o freeze the LCD reading press the HOLD button The HOLD icon appears on the LCD Press the HOLD button again to return to normal operation Relative Press the REL button REL will appear in the display t...

Страница 8: ...ry and store it separately Battery Replacement 1 Remove the 2 Phillips head screws that secure the rear battery cover 2 Open the battery compartment 3 Replace the 2 AAA 1 5V batteries 4 Secure the bat...

Страница 9: ...DC Voltage 600 VDC 1V 2 0 2 digits 400 0 0 1 1 0 4 digits 4 000k 0 001k 40 00k 0 01k 400 0k 0 1k 1 5 2 digits 4 000M 0 001M 2 5 3 digits Resistance 40 00M 0 01M 3 5 5 digits 40 00nF 0 01nF 4 0 20 digi...

Страница 10: ...emperature 20 C to 60 C 4 F to 140 F Operating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 2000meters 7000ft maximum Battery Two AAA...

Отзывы: