Introduction 

Thank you for selecting the Extech MA410 Clamp Meter. This meter measures AC Current, AC/DC 
Voltage, Resistance, Capacitance, Frequency, Diode Test, Duty Cycle and Continuity. Custom 
features include Thermocouple Temperature and Non-Contact Voltage detection. The double molded 
case is designed for heavy duty use. This meter is shipped fully tested and calibrated and, with proper 
use, will provide years of reliable service. Extech Instruments is an ISO-9001 Certified company. 

Safety 

International Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user must refer 
to the manual for further information. 
 
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous 
voltages may be present 
 
Double insulation 

 

This 

WARNING

 symbol indicates a potentially hazardous situation, which if not 

avoided, could result in death or serious injury. 

This 

CAUTION

 symbol indicates a potentially hazardous situation, which if not 

avoided, may result damage to the product. 

 
 
 

PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY 

OVERVOLTAGE CATEGORY I 

Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which 
measures are taken to limit the transient over voltages to an appropriate low level. 
Note – Examples include protected electronic circuits. 

OVERVOLTAGE CATEGORY II 

Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from 
the fixed installation. 
Note – Examples include household, office, and laboratory appliances. 

OVERVOLTAGE CATEGORY III 

Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. 
Note – Examples include switches in the fixed installation and some equipment for industrial use 
with permanent connection to the fixed installation. 

OVERVOLTAGE CATEGORY IV 

Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. 
Note – Examples include electricity meters and primary over-current protection equipment

 

WARNING 

CAUTION 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MA410T

Страница 1: ...User Guide 400Amp True RMS AC Clamp Meter NCV Model MA410T www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...ndicates a potentially hazardous situation which if not avoided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY...

Страница 3: ...r fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when making measurements if the vo...

Страница 4: ...t rear 13 Positive input jack Display icons Description HOLD Data Hold AUTO Autoranging DC Direct Current AC Alternating Current Low battery REL Relative V Volts Voltage Ohms Resistance A Amperes Curr...

Страница 5: ...light NOTE The conductors in electrical cord sets are often twisted For best results move the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor NO...

Страница 6: ...lay Frequency 7 Press the Hz button to display Duty Cycle Resistance Diode Continuity Measurements Note Remove power from the device under test before making resistance measurements 1 Set the function...

Страница 7: ...o freeze the LCD reading press the HOLD button The HOLD icon appears on the LCD Press the HOLD button again to return to normal operation Relative Press the REL button REL will appear in the display t...

Страница 8: ...ry and store it separately Battery Replacement 1 Remove the 2 Phillips head screws that secure the rear battery cover 2 Open the battery compartment 3 Replace the 2 AAA 1 5V batteries 4 Secure the bat...

Страница 9: ...DC Voltage 600 VDC 1V 2 0 2 digits 400 0 0 1 1 0 4 digits 4 000k 0 001k 40 00k 0 01k 400 0k 0 1k 1 5 2 digits 4 000M 0 001M 2 5 3 digits Resistance 40 00M 0 01M 3 5 5 digits 40 00nF 0 01nF 4 0 20 digi...

Страница 10: ...emperature 20 C to 60 C 4 F to 140 F Operating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 2000meters 7000ft maximum Battery Two AAA...

Отзывы: