Operation 

NOTES

: Read and understand all 

Warning

 and 

Caution

 statements in this operation manual prior 

to using this meter. Set the function select switch to the OFF position when the meter is not in use. 
 

Non-Contact Voltage Detector 

WARNING:  

Risk of Electrocution. Before use, always test the Voltage Detector on a known live 

circuit to verify proper operation

1. 

Rotate the Function switch to any measurement position. 

2. 

Place the detector probe tip on the conductor to be tested. 

3. 

If AC voltage is present, the NCV detector light will turn on with 
a steady red light. 

NOTE

: The conductors in electrical cord sets are often twisted. For 

best results, move the probe tip along a length of the cord to 
assure placing the tip in close proximity to the live 
conductor. 

NOTE

: The detector is designed with high sensitivity. Static 

electricity or other sources of energy may randomly trip the sensor. This is normal operation. 

 
 
 

AC Current Measurements  

 

WARNING: 

Disconnect the test leads before making clamp measurements. 

 

1.  Rotate the Function switch to the 

400A

 position 

2.  Press the trigger to open jaw. Fully enclose 

only one conductor. 

3.  Read the current value in the display. 
4.  If the value is less than 40A, rotate the function 

switch to the 

40A

 position to improve 

resolution. 

 

 

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MA410T

Страница 1: ...User Guide 400Amp True RMS AC Clamp Meter NCV Model MA410T www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...ndicates a potentially hazardous situation which if not avoided may result damage to the product PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLTAGE CATEGORY...

Страница 3: ...r fuses Inspect the condition of the test leads and the meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when making measurements if the vo...

Страница 4: ...t rear 13 Positive input jack Display icons Description HOLD Data Hold AUTO Autoranging DC Direct Current AC Alternating Current Low battery REL Relative V Volts Voltage Ohms Resistance A Amperes Curr...

Страница 5: ...light NOTE The conductors in electrical cord sets are often twisted For best results move the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor NO...

Страница 6: ...lay Frequency 7 Press the Hz button to display Duty Cycle Resistance Diode Continuity Measurements Note Remove power from the device under test before making resistance measurements 1 Set the function...

Страница 7: ...o freeze the LCD reading press the HOLD button The HOLD icon appears on the LCD Press the HOLD button again to return to normal operation Relative Press the REL button REL will appear in the display t...

Страница 8: ...ry and store it separately Battery Replacement 1 Remove the 2 Phillips head screws that secure the rear battery cover 2 Open the battery compartment 3 Replace the 2 AAA 1 5V batteries 4 Secure the bat...

Страница 9: ...DC Voltage 600 VDC 1V 2 0 2 digits 400 0 0 1 1 0 4 digits 4 000k 0 001k 40 00k 0 01k 400 0k 0 1k 1 5 2 digits 4 000M 0 001M 2 5 3 digits Resistance 40 00M 0 01M 3 5 5 digits 40 00nF 0 01nF 4 0 20 digi...

Страница 10: ...emperature 20 C to 60 C 4 F to 140 F Operating Humidity Max 80 up to 31 C 87 F decreasing linearly to 50 at 40 C 104 F Storage Humidity 80 Operating Altitude 2000meters 7000ft maximum Battery Two AAA...

Отзывы: