background image

EX430A-en-GB_v6.0   7/16 

11

CONTACT TEMPERATURE MEASUREMENTS 

1.  Set the function switch to the black Type K 

ºC

 or 

ºF

 position. 

2.  Insert the Temperature Probe into the input jacks, making sure to 

observe the correct polarity. 

3.  Touch the Temperature Probe head to the part whose temperature you 

wish to measure. Keep the probe touching the part under test until the 
reading stabilizes (about 30 seconds). 

4.  Read the temperature in the display. 
 

Note:

 The temperature probe is fitted with a type K mini connector. A mini 

connector to banana connector adaptor is supplied for connection to 
the input banana jacks. 

 
 
 
 
 
 
 
 
 

AUTORANGING/MANUAL RANGE SELECTION 

When the meter is first turned on, it automatically goes into AutoRanging. This automatically selects 
the best range for the measurements being made and is generally the best mode for most 
measurements. For measurement situations requiring that a range be manually selected, perform 
the following: 

1. 

Press the RANGE key. The 

AUTO

 display indicator will turn off. 

2. 

Press the RANGE key to step through the available ranges until you select the range you want. 

3. 

To exit the Manual Ranging mode and return to AutoRanging, press and hold the RANGE key for 
2 seconds. 

Note:

 Manual ranging does not apply for the Capacitance, Frequency and Temperature functions. 

RELATIVE MODE 

The relative measurement feature allows you to make measurements relative to a stored reference 
value. A reference voltage, current, etc. can be stored and measurements made in comparison to 
that value. The displayed value is the difference between the reference value and the measured 
value. 

1. 

Perform the measurement as described in the operating instructions. 

2. 

Press the REL button to store the reading in the display and the "REL" indicator will appear on 
the display. 

3. 

The display will now indicate the difference between the stored value and the measured value. 

4. 

Press the REL button to exit the relative mode. 

Note:

 The Relative function does not operate in the Frequency function. 

 

DISPLAY BACKLIGHT 

Press the      key for to turn on or off the display backlight function.  

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание EX430A

Страница 1: ...USER MANUAL True RMS Multimeter Extech EX430A www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...potentially hazardous situation which if not avoided could result in death or serious injury This CAUTION symbol indicates a potentially hazardous situation which if not avoided may result damage to t...

Страница 3: ...ion to the recessed electrical contacts Other means should be used to ensure that the terminals are not live If the equipment is used in a manner not specified by the manufacturer the protection provi...

Страница 4: ...C DC 500mA 600V fast acting fuse A AC DC 10A 600V fast acting fuse 30 seconds max every 15 minutes Frequency Resistance Capacitance Duty Cycle Diode Test Continuity 250Vrms for 15sec max Temperature 6...

Страница 5: ...Symbols and Annunciators Continuity Diode test Battery status Test lead connection error n nano 10 9 capacitance micro 10 6 amps cap m milli 10 3 volts amps A Amps k kilo 103 ohms F Farads capacitanc...

Страница 6: ...ut sensitivity The reading will stabilize and give a proper measurement when connected to a circuit DC VOLTAGE MEASUREMENTS CAUTION Do not measure DC voltages if a motor on the circuit is being switch...

Страница 7: ...the display DC CURRENT MEASUREMENTS CAUTION Do not make current measurements on the 10A scale for longer than 30 seconds Exceeding 30 seconds may cause damage to the meter and or the test leads 1 Ins...

Страница 8: ...en open up the circuit at the point where you wish to measure current 7 Touch the black test probe tip to the negative side of the circuit Touch the red test probe tip to the positive side of the circ...

Страница 9: ...than approximately 150 the audible signal will sound If the circuit is open the display will indicate OL DIODE TEST 1 Set the function switch to the green position 2 Insert the black test lead banana...

Страница 10: ...lay FREQUENCY MEASUREMENTS 1 Set the rotary function switch to the green Hz position 2 Insert the black lead banana plug into the negative COM jack and the red test lead banana plug into the positive...

Страница 11: ...tor will turn off 2 Press the RANGE key to step through the available ranges until you select the range you want 3 To exit the Manual Ranging mode and return to AutoRanging press and hold the RANGE ke...

Страница 12: ...n the battery voltage becomes low Replace the battery when this appears WRONG CONNECTION INDICATION The icon will appear in the upper right conner of the display and the buzzer will sound whenever the...

Страница 13: ...001A 2 5 reading 5 digits 10A 0 01A AC Current 50 to 400Hz 400Hz to 1KHz 400 A 0 1 A 1 8 reading 8 digits 3 0 reading 7 digits 4000 A 1 A 40mA 0 01mA 400mA 0 1mA 4A 0 001A 3 0 reading 8 digits 3 5 re...

Страница 14: ...res Type K thermocouple Input Impedance 7 5M VDC VAC AC Response True rms ACV Bandwidth 50Hz to 1kHz Display 4000 count backlit LCD Over range indication OL is displayed Auto Power Off 15 minutes appr...

Страница 15: ...removed to prevent damage to the unit Battery Replacement 1 Remove the Phillips head screw that secures the rear battery door 2 Open the battery compartment 3 Replace the 9V battery 4 Secure the batte...

Страница 16: ...ar cover 5 Lift the center circuit board straight up from the connectors to gain access to the fuse holders 6 Gently remove the old fuse and install the new fuse into the holder 7 Always use a fuse of...

Отзывы: