background image

BATTERY  TESTER

INSTRUCTION  MANUAL

Summary of Contents for BST-BT01

Page 1: ...BATTERY TESTER INSTRUCTION MANUAL ...

Page 2: ...Index 1 Introduction 2 Safety notes 3 Features 4 Specifications 5 Instrument layout 6 Measurement 7 Maintenance Page 1 2 3 4 5 6 7 8 9 ...

Page 3: ...een designed and tested according to CE safety requirements for electronic measuring apparatus IEC EN 61010 1 and other safety standards Follow all warnings to ensure safe operation WARNING READ SAFETY NOTES NEXT PAGE BEFORE USING THE METER ...

Page 4: ... impaired Rated environmental conditions 1 Indoor Use 2 Installation Category I 100V 3 Pollution Degree 2 4 Altitude up to 2000 meters 5 Relative humidity 80 max 6 Ambient temperature 0 40 C Observe the International Electrical Symbols listed below Meter is protected throughout by double insulation or reinforced insulation Warning Risk of electric shock Caution Refer to this manual before using th...

Page 5: ...on line Impedance measure signal used 1kHz AC frequence Test lead used 4 wire measurement method can reduce contact resister 2000 count LCD DC Voltage measurement 4 wire impedance measurement Data Hold function Low battery indication 9VDC power supply Measure batteries type Li ion Ni Cd Ni MH ...

Page 6: ... 2000mΩ 1mΩ 3 rdg 3dgt 20Ω 10 mΩ 3 rdg 3dgt General Dimensions 192mm L x88 6mm W x45 2mm D Weight Approx 360 g battery included Power source battery 9V x1 Low Battery Indication sign appears on the display when the battery voltage drops below accurate operating level Safety Standard EN 61010 1 CAT I 100V EN 61326 1 EN 55011 EN 61000 4 2 EN 61000 4 3 Accessories Test leads Battery Instruction Manua...

Page 7: ... 5 5 Instrument layout 1 Function Switch 2 LCD Display 3 Sense Terminal 4 Source Terminal 5 Sense Terminal 6 Source Terminal 7 HOLD Button 4 7 6 3 5 1 2 ...

Page 8: ...onnect 4 Source Terminal This is the positive input terminal for voltage ohm measurement Use the RED test lead to connect 5 Sense Terminal This is the positive input terminal for voltage ohm measurement Use the BLACK test lead to connect 6 Source Terminal This is the positive input terminal for voltage ohm measurement Use the BLACK test lead to connect 7 HOLD Button Pressing the HOLD button preven...

Page 9: ...d tip and the battery The reading will be displayed on the LCD screen Warning 1 Use caution in the presence of voltage above DC 100V as these pose a shock hazard 2 Can t measure AC voltage otherwise electrical circuits can be dangerous Battery impedance measurement 1 Insert the RED test lead to Sense and Source terminal and the BLACK test lead to Sense and Source terminal 2 Rotate function switch ...

Page 10: ...ew batteries as follows 1 Disconnect the test leads from the instrument and turn off the power 2 Unscrew the case and replace with new battery 3 Close the case and lock the screw Warning To avoid electrical shock or damage to the meter do not get water inside the case Battery 9V ...

Page 11: ...s performed at the source of the low voltage installations CAT III For measurements performed in building installations CAT II For measurements performed on circuits directly connected to the low voltage installations CAT I For measurements performed on circuits not directly connected to mains Due to our policy of constant improvement and development we reserve the right to change specifications w...

Page 12: ... 10 ...

Reviews: