background image

EA20-EN V1.8   3/14 

2

Introduction

 

Congratulations

 

on

 

your

 

purchase

 

of

 

the

 

Extech

 

EasyView™

 

EA20

 

Digital

 

Hygro

Thermometer.

 

This

 

device

 

measures

 

Humidity,

 

Temperature,

 

Dew

 

Point

 

temperature

 

and

 

Wet

 

Bulb

 

temperature.

 

Advanced

 

features

 

include

 

Manual

 

Datalogging

 

of

 

up

 

to

 

99

 

sets,

 

MAX/MIN

 

recording,

 

Relative

 

measurement

 

mode,

 

and

 

elapsed

 

timer.

 

Careful

 

use

 

of

 

this

 

meter

 

will

 

provide

 

years

 

of

 

reliable

 

service.

 

 

Meter

 

Description

 

1.

 

Humidity/Temperature

 

Probe

 

2.

 

Multifunction

 

LCD

 

with

 

bargraph

  

and

 

status

 

indicators

 

3.

 

Power

 

ON/OFF

 

button

 

4.

 

MX/MN

 

button

 

5.

 

DATA

 

HOLD

 

button

 

6.

 

Humidity

 

/

 

Temperature

 

select

  

button

 

7.

 

TIME

 

button

 

(for

 

MX/MN

 

elapsed

  

timer)

 

8.

 

Temperature

 

units

 

(C/F)

 

select

  

button

 

9.

 

DEW

 

POINT

 

temperature

 

select

  

button

 

10.

 

RELATIVE

 

mode

 

button

 

11.

 

WET

 

BULB

 

temperature

 

select

  

button

 

12.

 

MEM

 

key

 

manual

 

datalogging

  

control

 

key

 

13.

 

READ

 

key

 

manual

 

memory

 

data

 

reading

 

control

 

key

 

14.

 



keys

 

to

 

select

 

memory

  

location

 

Note:

 

The

 

battery

 

compartment

 

is

 

located

  

on

 

the

 

rear

 

of

 

the

 

instrument

 

9

3

6

4

7
8

5

2

  

1

Содержание EasyView EA20

Страница 1: ...User s Guide EasyView Digital Hygro Thermometer and Datalogger Model EA20 ...

Страница 2: ...ervice Meter Description 1 Humidity Temperature Probe 2 Multifunction LCD with bargraph and status indicators 3 Power ON OFF button 4 MX MN button 5 DATA HOLD button 6 Humidity Temperature select button 7 TIME button for MX MN elapsed timer 8 Temperature units C F select button 9 DEW POINT temperature select button 10 RELATIVE mode button 11 WET BULB temperature select button 12 MEM key manual dat...

Страница 3: ...are available in the MX MN mode a Maximum and Minimum humidity with its associated temperature reading b Maximum and Minimum temperature with its associated humidity reading c Maximum and Minimum Dew point temperature with its associated standard temperature or humidity d Maximum and Minimum Wet Bulb temperature with associated standard temperature or humidity To exit the MX MN mode press and hold...

Страница 4: ...ture and stored reference values To store a humidity temperature reading group as a reference press the REL button when the desired reference readings are on the LCD the triangle icon will appear steady in the upper left hand corner of the LCD All subsequent displayed readings will be relative to the stored reference value For example if the reference values are 50 0 100 F and the actual readings ...

Страница 5: ... use solvents or abrasives 2 Store the meter in an area with moderate temperature and humidity refer to the operating and storage range in the specifications chart earlier in this manual Battery Replacement When the battery power falls low the BT symbol will appear on the LCD Replace the six 6 1 5 AAA batteries by removing the rear center battery compartment screw and accessing the battery compart...

Отзывы: