background image

EA20-EN V1.8   3/14 

5

Specifications

 

Function

 

Range

 

and

 

Resolution

Accuracy

 

Humidity

 

10.0

 

to

 

95.0%

 

RH

±3%

 

RH

 

(at

 

25

o

C,

 

30

 

to

 

95%

 

RH

 

)

±5%

 

RH

 

(at

 

25

o

C,

 

10

 

to

 

30%

 

RH

 

)

 

Temperature

 

4

 

to

 

140

o

F

 

(

20

 

to

 

60

o

C)

±1.8

o

F

 

(±1

o

C)

Dew

 

Point

 

4

 

to

 

140

o

F

 

(

20

 

to

 

60

o

C)

calculated

 

Wet

 

Bulb

 

4

 

to

 

140

o

F

 

(

20

 

to

 

60

o

C)

calculated

 

Display

 

 

Multifunction

 

LCD

 

with

 

bargraph

 

and

 

status

 

indicators

 

Sensor

 

Type

 

 

Humidity:

 

Precision

 

capacitance

 

sensor

 

Temperature:

 

Thermistor

 

Response

 

Time

 

Humidity:

 

45%

 

to

 

95%

 

<

 

1

 

min;

 

95%

 

to

 

45%

 

<

 

3

 

min.

 

Temperature:

 

Approx.

 

2

 

seconds

 

for

 

a

 

10

o

C

 

change

 

Sampling

 

Rate

 

 

2

 

times

 

per

 

second

 

Datalogging

  

Memory

  

99

 

sets

 

Operating

 

Conditions

 

32

 

to

 

140

o

F

 

(0

 

to

 

60

o

C);

 

<

 

95%

 

RH

 

non

condensing

 

Storage

 

Conditions

 

14

 

to

 

140

o

F

 

(

10

 

to

 

60

o

C);

 

<70%

 

RH

 

non

condensing

 

Power

 

Supply

 

6

 

x

 

1.5V

 

‘AAA’

 

batteries

 

with

 

programmable

 

auto

 

power

 

off

 

(1

 

minute

 

to

 

59

 

minutes

 

in

 

7

 

selectable

 

times)

 

Battery

 

Life

 

 

Approx.

 

200

 

hours

 

Dimensions

 

/

 

Weight

 

5.9

 

x

 

2.8

 

x

 

1.4”

 

(150

 

x

 

72

 

x

 

35mm);

 

8.3

 

oz.

 

(235g)

 

 

Maintenance

 

Cleaning

 

and

 

storage

 

1.

 

The

 

meter

 

should

 

be

 

cleaned

 

with

 

a

 

damp

 

cloth

 

and

 

mild

 

detergent

 

when

 

necessary.

 

Do

 

not

 

use

 

solvents

 

or

 

abrasives.

 

2.

 

Store

 

the

 

meter

 

in

 

an

 

area

 

with

 

moderate

 

temperature

 

and

 

humidity

 

(refer

 

to

 

the

 

operating

 

and

 

storage

 

range

 

in

 

the

 

specifications

 

chart

 

earlier

 

in

 

this

 

manual).

 

Battery

 

Replacement

 

When

 

the

 

battery

 

power

 

falls

 

low,

 

the

 

‘BT’

 

symbol

 

will

 

appear

 

on

 

the

 

LCD.

 

Replace

 

the

 

six

 

(6)

 

1.5

 

‘AAA’

 

batteries

 

by

 

removing

 

the

 

rear

 

(center)

 

battery

 

compartment

 

screw

 

and

 

accessing

 

the

 

battery

 

compartment.

 

Observe

 

polarity

 

when

 

placing

 

the

 

batteries

 

in

 

the

 

compartment.

 

Ensure

 

that

 

the

 

compartment

 

cover

 

is

 

securely

 

fastened

 

when

 

finished.

 

Warranty

 

does

 

not

 

apply

 

to

 

defects

 

resulting

 

from

 

action

 

of

 

the

 

user

 

such

 

as

 

misuse,

 

improper

 

wiring,

 

operation

 

outside

 

of

 

specification,

 

improper

 

maintenance

 

or

 

repair,

 

or

 

unauthorized

 

modification.

 

Extech

 

specifically

 

disclaims

 

any

 

implied

 

warranties

 

or

 

merchantability

 

or

 

fitness

 

for

 

a

 

specific

 

purpose

 

and

 

will

 

not

 

be

 

liable

 

for

 

any

 

direct,

 

indirect,

 

incidental

 

or

 

consequential

 

damages.

 

Extech's

 

total

 

liability

 

is

 

limited

 

to

 

repair

 

or

 

replacement

 

of

 

the

 

product.

 

The

 

warranty

 

set

 

forth

 

above

 

is

 

inclusive

 

and

 

no

 

other

 

warranty,

 

whether

 

written

 

or

 

oral,

 

is

 

expressed

 

or

 

implied.

 

 
 

 

Copyright

 

©

 

2014

 

FLIR

 

Systems,

 

Inc.

 

Reservados

 

todos

 

los

 

derechos,

 

incluyendo

 

el

 

derecho

 

de

 

reproducción

 

total

 

o

 

parcial

 

en

 

cualquier

 

medio

 

www.extech.com

 

Содержание EasyView EA20

Страница 1: ...User s Guide EasyView Digital Hygro Thermometer and Datalogger Model EA20 ...

Страница 2: ...ervice Meter Description 1 Humidity Temperature Probe 2 Multifunction LCD with bargraph and status indicators 3 Power ON OFF button 4 MX MN button 5 DATA HOLD button 6 Humidity Temperature select button 7 TIME button for MX MN elapsed timer 8 Temperature units C F select button 9 DEW POINT temperature select button 10 RELATIVE mode button 11 WET BULB temperature select button 12 MEM key manual dat...

Страница 3: ...are available in the MX MN mode a Maximum and Minimum humidity with its associated temperature reading b Maximum and Minimum temperature with its associated humidity reading c Maximum and Minimum Dew point temperature with its associated standard temperature or humidity d Maximum and Minimum Wet Bulb temperature with associated standard temperature or humidity To exit the MX MN mode press and hold...

Страница 4: ...ture and stored reference values To store a humidity temperature reading group as a reference press the REL button when the desired reference readings are on the LCD the triangle icon will appear steady in the upper left hand corner of the LCD All subsequent displayed readings will be relative to the stored reference value For example if the reference values are 50 0 100 F and the actual readings ...

Страница 5: ... use solvents or abrasives 2 Store the meter in an area with moderate temperature and humidity refer to the operating and storage range in the specifications chart earlier in this manual Battery Replacement When the battery power falls low the BT symbol will appear on the LCD Replace the six 6 1 5 AAA batteries by removing the rear center battery compartment screw and accessing the battery compart...

Отзывы: