background image

14 

365535-en-GB_V1.2   1/15 

Before starting the timer, enter a countdown time first. Then press [START] to start timer running. When the timer 
counts down to zero, a 3 second beep ... beep sound will be generated for a timer setting within one minute; 15 
second beep ... beep sound for 1 minute to 10 minutes setting and 30 second beep ... beep sound for over 10 
minutes. Pressing any key will stop the beep sound. 

Under CR operation mode, the timer value will be reloaded and count down will start again. The timer cycle 

counter will be increased by one and updated on the display. 

Under CS operation mode, the timer, after counting down to 0:00'00", will stay at 0:00'00"0 until you press [RESET] 
to reload the timer value. 
Under CU operation mode, the timer, after counting down to 0:00'00"0, will count up and stop at 19:59'59"9.  

 

How to set the timer 

Press and hold [RECALL] for 2 seconds to activate timer setting. Timer setting starts with second digits, which 
are shown blinking. You can press [START] to advance the flashing digits. Or you can press [RESET] to select 
other digits. The setting is in sequence of second, minute, hour and timer operating mode (CR, CS and CU). 
NOTE: You can only set Hour, Minute and Seconds. The 1/10 second cannot be set. 
 
Press and hold [RECALL] for 2 seconds.  
Timer setting starts with second digits. 

Press [RESET] to move to minute digits. 

Press [RESET] further to go to 
hour digits. Hour digits can be  
adjusted from 0 to 19. 

{000} 0:00’00”0 
CR 0:00’

00

”0 

A 12:58’55

{000} 0:00’00”0 
CR 0:

00

’00”0 

A 12:58’57

{000} 0:00’00”0 
CR 

0

:00’00”0 

 A 

12:59’02 

Содержание 365535

Страница 1: ...User s Guide Digital Stopwatch Model 365535...

Страница 2: ...modes Countdown Repeat Countdown Stop Countdown then count up for countdown timer Stroke measurement basing on 3 Decimal second minute and hour chronograph Segmented run memory Beep sound selectable L...

Страница 3: ...as noted above 1 Normal time mode 2 Alarm time mode 3 Chronograph and Recall mode 4 Data mode 300M 500M Models only 5 Count down timer mode 6 Pacer mode 7 Stroke measurement mode Button Operation Mode...

Страница 4: ...your stopwatch is NORMALTIME If NORMALTIME is not displayed press Mode until it is Year 2001 Date January 1 Dayof week Monday Time 12 00 am The display format is as below During clock display press S...

Страница 5: ...etting Let the current status be ON Press START to toggle Sound ON or OFF Display for contrast adjustment Let the current contrast be 5 Press START consecutively to advance the contrast up to 16 then...

Страница 6: ...ton to stop the alarm sound Setting Alarm Time Press and hold RECALL for 2 seconds to activate the alarm setting The alarm minute digits will flash as an indication Adjust the flashing digit by pressi...

Страница 7: ...me Meanwhile the lap and split time will be frozen for 5 seconds After this 5 second period the lap and split time will return to normal In addition the fastest lap the slowest lap and the averages of...

Страница 8: ...te as a normal 1 100 second chronograph as well as decimal minute decimal second and decimal hour chronograph As you press MODE to enter the chronograph mode the normal 1 100 second chronograph displa...

Страница 9: ...ph mode to enter DATA mode when the stopwatch has been stopped Records for different segments can be recalled read or deleted Detailed operation in DATA mode is described in Data Mode section below Ch...

Страница 10: ...rts from the last record to the first record when the stopwatch is running and vice versa when the stopwatch has been stopped RECALL RECALL RECALL SLOW 001 0 00 07 63 SPLIT 0 00 07 63 LAP 0 03 10 16 S...

Страница 11: ...ART STOP or LAP SPLIT to exit from chrono recall mode and jump to the chrono start stop or lap state respectively Data Mode Press MODE until you enter DATA mode The mode message DATA will be shown for...

Страница 12: ...segment you want you can press RECALL button consecutively to read the lap records from the first to the last lap As you continue to press RECALL during the display of the last lap you can advance to...

Страница 13: ...and DELETE ALL will show on the display If you don t want to delete the records you can press any key to exit DELETE ALL state before the end of the ready period and resume the display of the segment...

Страница 14: ...ess RESET to reload the timer value Under CU operation mode the timer after counting down to 0 00 00 0 will count up and stop at 19 59 59 9 How to set the timer Press and hold RECALL for 2 seconds to...

Страница 15: ...flashing to indicate that the pace count is ready for setting Press RESET to select the pace count Once the desired pace count is selected press START to confirm the setting and start the pace count...

Страница 16: ...t second the display will become steady If measurement is stopped in the first second stroke frequency 180 error signal Err will be shown After the first second has elapsed the instantaneous measureme...

Отзывы: