![EXPO ML384 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/expo/ml384/ml384_manual_2452094004.webp)
Page
1
ML435 | v23
Expo Technologies UK
T: +44 (0) 20 8398 8011
Expo Technologies US
T: +1 (440) 247 5314
Expo Technologies China
T: +86 532 8906 9858
Section 1: System Specification
5 X LC / ss / ET / IS / OV / PC
Size
5 = MiniPurge
®
Purge flow rate:
6000 NI/min
Approval / Certification
Sira 01ATEX1295X
0518
II 2(2) GD
Ex [pxb] ia IIC T5 Gb
Ex [pxb] ia IIIC T100ºC Db
T
amb
-20ºC to +55ºC
IECEx SIR07.0027X
Ex [pxb] ia IIC T5 Gb
Ex [pxb] ia IIIC T100ºC Db
T
amb
-20ºC to +55ºC
TÜV 12.1462X
Ex [pxb] ia IIC T6 Gb
Ex [pxb] ia IIIC T95ºC Db
T
amb
-20ºC to +55ºC
OV
= Purge Outlet Valve is pneumatically
operated
IS
= Intrinsically Safe Power & Alarm
terminal box
Timing Method
ET
= Electronic Timer
MiniPurge
®
Housing
ss
= Stainless Steel 316L
Pressurization Method
LC
= Leakage Compensation
ATEX Certificate:
IECEx Certificate:
TÜV INMETRO Certificate:
PC
= Pressurized Control. Automatic
leakage compensation (CLAPS)
FM Certificate (USA and Canada):
FM 1X8A4.AE
Class I Div 1 Groups A B C & D
Type X Pressurization
T
amb
-20ºC to +60ºC
Refer to Section 13 of this manual for FM
specific manual ML384
For limitations and conditions of use refer
to the applicable certificates in Appendix A
of this manual.