![Exodraft Xzense Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/exodraft/xzense/xzense_instruction-manual_2451378047.webp)
3111001 Xzense UK 20190731
47
Technical specifications
5.3. User and service menu
MENU
SUBMENU
TYPE
DESCRIPTION
FACTORY SETTING
GENERAL
Interface
Language
Language selection shown in the menus:
Danish, Swedish, Norwegian, German, English,
French, Dutch, Polish and Finnish
English
Contrast
Contrast from 0-100%
50%
Brightness
Brightness from 0-100%
100%
Sound
Sound from 0-100%
100%
Setup
Start temperature
Automatic start when temperature sensor
measures: 5–100 °C
40 °C
Stop temperature
Automatic stop when temperature sensor
measures: 0–95 °C
35 °C
Boost time
Time setting at startup (Boost): 1-15 min.
10 min.
Stop time (Afterrun)
Time setting at stop (Afterrun): 1-200 min
30 min.
Boost speed
Boost speed from 40-100%
100%
Chimney draft
Chimney draft from 8-60 Pa
12 Pa
Minimum fan speed
Minimum voltage level: 80 -120 V.
Note: Min. 100 V if the chimney fan is an
RS009.
100 V
Eternal start
Fatory reset
Restores all factory settings: Yes/No
No
Error log
Displays errors and alarms with date
Software version
Displays software version for enabled units:
control panel, power unit, repeater and pres-
sure sensor
System control
Control systems in the unit:
Manuel/eXotelligence/ Pressure controlled
Manual
Temperature sensor
Activation of temperature sensor: On/Off
On
Alarm setpoint
High temperature alarm deviation setting:
150-400 °C
330 °C
Boost stop setpoint
Stop temperature for boost
150 °C
Network
Signal
Devices
Add power unit, repeater and pressure sensor
Signal test
Displays the status of the signal
Reset network
Deletes all included devices: Yes/No
Note: Also deletes the power unit from the
network
No
Bluetooth
Enable Bluetooth
Activating Bluetooth function: On/Off
Off