Daily use
Using the
EFC controller
•
Press the ON/OFF button (A).
•
The operating LED (B) will flash GREEN until the correct chimney draught is confirmed.
•
If it flashes YELLOW, then the Air inlet must be opened The operating LED will then
become GREEN and the fireplace can be lit.
•
To stop the fan press the ON/OFF button.
External
ON/OFF switch
•
The ON/OFF switch can be used to start, stop and reset the controller.
•
If the external ON/OFF switch is used, it has priority over the control panel and the remote control.
NB!
The switch must be in the OFF position before the controller can be re-started.
Operating LED
Observation (B)
Type of fault
Flashing RED
No start-up signal from the safety circuit Typically, because the fan is restarted while it is still running
Flashing GREEN
The fan has started and the controller is waiting for the chimney-draught-ok signal
Flashing YELLOW
Chimney draught is confirmed correct but signal from the Air inlet is missing
Constant GREEN
Start up ok and the fire can be lit
Constant YELLOW
The ventilation function is active and the fire is OFF
Alarm LED
Constant RED indicates a power failure has occured.
To reset and start the controller, press the ON/OFF button once. If the alarm LED (C) activates during ope
-
ration, press the ON/OFF button twice to stop the fan and restart the controller. If the alarm LED remains on
after reset, please refer to the “Troubleshooting” section.
Extra function
Press the ON/OFF button (A) for at least four seconds to increase the fan’s operating speed. If the controller
is switched off, the fan speed will be reset.
B
A
C
Содержание EFC21
Страница 1: ...Your energy Optimized Controls EFC21 UK Read and save these instructions...
Страница 2: ......
Страница 22: ......
Страница 23: ......