![Exlar Curtiss-Wright Tritex TTX Series Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/exlar/curtiss-wright-tritex-ttx-series/curtiss-wright-tritex-ttx-series_installation-and-service-instructions-manual_2450855035.webp)
TTX Series DC Actuator Installation & Maintenance Instructions |
35
www.exlar.com
| 952.500.6200
9.3 CBL-T2USB485-M8xxx COMMUNICATIONS CABLE
xxx = cable length in ft. Standard lengths: 15, 25, 50 ft
Specifications
Contact Carrier Material / Color Nylon or PUR / Black
Molded Head Material Color
Thermoplastic PUR / Yellow
Contact Material / Plating
Brass / Gold
Coupling Nut Material / Plating
Brass / Nickel
Rated Current [A]
2.0 A
Rated Voltage [V]
125 Vdc
Outer Jacket Material / Color
PUR / Black
Conductor Insolation Material
PVC
Number of Conductors [AWG]
3x24 AWG
Drain / Shield
26 AWG Drain / Foil
Temperature Range
-40 °C to +105 °C (-40 °F to +221 °F)
Protection Class
Meets NEMA 1, 3, 4, 6P & IEC
IP67
Communication Converter
When connecting the Tritex TTX080 RS485 port to PC, a
communication converter will typically be required.
Exlar offers a USB to RS485 converter with an M8 connector
ready to connect to the Tritex TTX080 port. Model # CBL-
T2USB485-M8-xxx. This converter is not isolated and is not
recommended for permanent installation.
CAUTION!
If another master is on the network such as
PLC or HMI, this converter must be removed from the RS485
end. Leaving it connected with the USB end unconnected will
load down the RS485 network and not allow it to function.
4
3
1
2
Male End View
1=Brown
2=Drain
3=Blue
4=Black
M23 x 1
Ø26.0 [1.02]
83.2 [3.27]
Ø10.2 [0.40]
25.4 [1.0]
100.0 [3.94]
7.0 [0.28]