![Exlar Curtiss-Wright Tritex TTX Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/exlar/curtiss-wright-tritex-ttx-series/curtiss-wright-tritex-ttx-series_installation-and-service-instructions-manual_2450855013.webp)
TTX Series DC Actuator Installation & Maintenance Instructions |
13
www.exlar.com
| 952.500.6200
4.0 ELECTRICAL INSTALLATION
4.1 INTRODUCTION
All the required power components, motion processor, I/O, and communications ports are contained in the actuator housing. Tritex
TTX DC models do not have an internal 24 Vdc power supply. External I/O Power is required for digital outputs and brake. SRC
+24 terminals are present on termination board but make no internal connection.
The following diagrams show the electrical connections schematically:
24V Power
24V Common
Output 1
Output 2
Output 3
Input 1
Input 2
Input 3
Input 4
Control Electronics
and Low Voltage
Circuits
DC Input +
DC Input -
I/O Common
RS485+
RS485-
IO +V
SRC +24V
PE
PE
4-20mA OUT +
4-20mA IN +
4-20mA IN -
4-20mA OUT -
RS485Common
Shield
GND
Logic Power
PE
IO +V
SRC +24V
Brake +V
Brake
(Optional)
+
-
Power
Supplies
Bus and Motor
Drivers
Jumper-
Figure 8
–
Electrical Diagram 4-20 mA