![Exlar Curtiss-Wright Tritex TTX Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/exlar/curtiss-wright-tritex-ttx-series/curtiss-wright-tritex-ttx-series_installation-and-service-instructions-manual_2450855029.webp)
TTX Series DC Actuator Installation & Maintenance Instructions |
29
www.exlar.com
| 952.500.6200
CAUTION!
Reversing polarity of the Bus Power (+) and
Power Common (-) will cause a short circuit, which must be
protected by the input fuse. See fusing below. If a fuse is not
installed the drive could be permanently damaged.
Power Supply Wiring and Fusing
Fuse
Wire
Bus Power
20 A 125 Vdc.
Bussmann type
ABC or similar.
12 AWG (4 mm
2
)
Logic Power
2 A 125 Vdc.
Bussmann type
ABC or similar.
18 AWG (1.5 mm
2
)
Twelve-gauge wire is recommended for bus power to reduce
voltage drop across the wire during peak power demands. If the
application does not require high peak or continuous power, the
wire gauge can be reduced, with a corresponding reduction in
fuse rating.
WARNING!
If the wire gauge for bus power is reduced
the fuse Amp rating must also be reduced in accordance with
wire size, type and local regulations.
5.8 GROUNDING
WARNING!
The actuator and all power supply PEs and
negative connections must be properly grounded using a single
point grounding method.
5.9 POWER SUPPLY CONNECTIONS
Power Connector Pin-Out, M23 Connectors, “I” Connector
Option
Signal
Pin for “I”
Connector
Option
Wire Color
TTIPC
“B”
Option
Bus Power (+)
12-48 Vdc
1
Blue
Red
Logic Power (+)
12-48 Vdc
3
White
Blue
Power Common (-)
4
Black
Black
PE (GND)
2
Green
Green
N/C (Reserved)
A
Orange N/A
N/C (Reserved)
B
Red
N/A
N/C (Reserved)
C
White/
Black
Light
Blue
N/C (Reserved)
D
Red/
Black
Light
Blue/
White
Insulation inserts:
E-Type, Front View
D
C
B
A
3
2
1
Power Connections on Terminal board 80 mm
Signal
Terminal
Label
Minimum Wire
AWG.
Bus Power (+)
12-48 Vdc
Bus +
12
Power Common (-) COMMON
12
Logic Power (+)
12-48 Vdc
LOGIC +
18
PE (GND)
PE
12
Figure 32
–
Grounding Diagram