Wiring - 3 Wire Connector / Satellite Relay Port
The Red satellite relay port can be used, if needed, to configure optional relays to energize
additional Ignition or Starter circuits, and Omega OEM security bypass interfaces also plug
into this port. Prewired dual relay sockets are available, and a plain 3-wire harness is
provided to use this port.
This 22 gauge Green wire is a 500mA Negative output having
basically the same operation as the 12 gauge Green Starter output wire. If two or more
Starter wires are present in the vehicle an optional relay is needed, connected to satellite
port Green wire as shown in the diagram.
22 Gauge Green Wire:
500mA ( - ) Starter Output
Connection If Needed.
The Red wire supplies constant 12 Volts that can be used to
power the relay's coil only- DO NOT use this Red wire for the optional relay(s) power
input (pin 87).
22 Gauge Red Wire:
( + ) Output For Optional Relay Coil
Connection If Needed.
Programming the Yellow/Green Wire
operation: Locate and open the small access panel
on the top of the control module case. Place the
Jumper as shown on the pins below the removable
panel on the control module. The factory setting is
the center “Ignition #2” position.
Accessory
Ignition #2
Starter
Jumper
18
11
•
Feature
#
3 is “Single or Double Pulse Activation”.
The “Double Pulse”
option allows the unit, in certain vehicles, to activate remote starting by
locking the vehicle doors two times with the original keyless entry transmitter. Exact
operations and vehicle suitability varies; consult with the installer for specific details.
•
Feature
#
5 is “Reset”
, and returns all Programmable Features to their factory default
settings. To do this, enter programming mode, select Feature
#
5, and press the brake
pedal once. The unit will acknowledge resetting the features turning off the parking
lights, flashing the Status Light once, and then immediately exiting programming mode
with the normal confirmation of 2 short and 1 long Status Light flashes and turning off the
parking lights.
Note: When a Programmable Features Reset is used, any feature which needs to be in
a setting different from the default setting will have to be reprogrammed.
•
Feature
#
4 is “Gasoline or Diesel Engine”.
When programming, press brake pedal
once for the “Gasoline” setting. Diesel engines have three options: pressing the brake
twice selects “Monitor Glow Plug Wire”, by which the unit delays engaging the starter
until its glow plug input wire detects the glow plugs turning off; and two preset delay
periods before starter engagement: 10 seconds (press brake 3 times) and 20 seconds
(press brake 4 times).
second (4 brake presses).