background image

Part No. F40BP72530002

Form No. BP7253-2

READ AND SAVE THESE INSTRUCTIONS

SW350, SR330 & SW375

Ceiling Fan/Light

Wall Control, Remote Control &

Receiver Owner's Manual

For use only with Emerson Ceiling Fan Models: F2100 2, F2200 2, F2300 1,

CF1 1, CF2300 1, CF2400 1, CF2454 2, CF2500 1, CF2600 2, CF2650 0,

CF2675 1, CF3500 0, CF3900 1, CF4500 4, CF4600 0 and CF4800 3.

Off

On

Up

Down

Lights

Select

Fan

Sleep

Flo

w

Secu

rit

y

Model

SW350

Wall Control

Lights

Fan

Select

Air

flow

Sleep

Security

Win

ter

Fan Low

Down Light

Fan High

Up Light

Air
DN

Air
UP

Model

SR330

Remote Control

Model

SW375

Receiver

NOTE: The SW350 and SR330 controls
must be used with a SW375 receiver.

BP7253-2  4/28/06  11:58 AM  Page 1

Содержание SR330

Страница 1: ...F2300 1 CF2400 1 CF2454 2 CF2500 1 CF2600 2 CF2650 0 CF2675 1 CF3500 0 CF3900 1 CF4500 4 CF4600 0 and CF4800 3 Off On Up Down Lights Select Fan Sleep Flow Security Model SW350 Wall Control Lights Fan Select Airflow Sleep Security Winter Fan Low Down Light Fan High Up Light Air DN Air UP Model SR330 Remote Control Model SW375 Receiver NOTE The SW350 and SR330 controls must be used with a SW375 rece...

Страница 2: ...n tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to ra...

Страница 3: ...T See NOTE 3 REMOVE WIRE CONNECTORS FROM RED AND BROWN WIRES See NOTE 1 3 BLUE WIRE BLACK WIRE WHITE WIRE CAP BLACK WIRE USING A WIRE CONNECTOR REMOVE WIRE CONNECTOR MOTOR COUPLING Figure 1 NOTE 2 On Model CF1 CF2400 and CF2800 Series Ceiling Fans the red and brown wires from the motor are connected to red and brown wires from the reversing switch Remove the wire connectors and separate these wire...

Страница 4: ...ellow wire supplied with fans containing built in Uplights through the hanger pipe until they extend about 4 out of the pipe Figure 4 5 Cut the harness wires approximately 3 from the end of the pipe Strip insulation 1 2 from end of wires 6 Using wiring connectors supplied connect the white red yellow blue and brown wires of the wiring harness to the white red yellow orange wire for early CF2400 Mo...

Страница 5: ...ed with steps 11 through 19 below 11 Position the ceiling cover over the hanger pipe Figure 8 Be sure the cover is oriented correctly with the large opening at the top 12 Install the hanger ball on the hanger pipe as follows Route the wiring harness connectors through the hanger ball and slide the hanger ball over the hanger pipe Install the pin through the holes at the top of the hanger pipe and ...

Страница 6: ... screws from existing switches Pull switches out from wall boxes and determine which wall box contains the hot lead and which wall box contains the load wire Also identify traveler wire s which are common to both wall boxes 16 Connect the black wire from the wiring harness to the black hot supply wire Figure 5 Connect the white wire from the wiring harness to the white neutral supply wiring Connec...

Страница 7: ... already connected to the black wire in the other wall box Secure with wire connectors supplied 7 STANDARD WIRING FOR EXISTING 3 WAY CONTROLS HOT BLK TRAVELER WIRES BLACK LOAD EXISTING WALL CONTROL SW350 WALL CONTROL BLK BLK BLK BLACK LOAD TRAVELER WIRES HOT BLK Off On Up Down Lights Fan Sleep Off On Up Down Lights Fan Sleep 3 WAY WIRING DIAGRAM RETROFIT Figure 13 Do not connect any neutral white ...

Страница 8: ...e SW375 Receiver If any changes have been made to the fan or light functions using the SW350 Wall Control those changes are not indicated on the remote LCD display When the SR330 Remote Control buttons are pressed the fan and light functions change to the LCD display settings Off On Up Down Lights Fan Sleep YELLOW WIRE TO YELLOW WIRE Built in Up Light Only BLUE WIRE TO BLUE WIRE SW375 RECEIVER WIR...

Страница 9: ...he Up Down arrow buttons without disabling the Sleep function The fan will continue to decrease by one speed every 60 minutes until the fan is on low speed NOTE The Code Learning Procedure must be performed before the wall control will operate the fan or light NOTE An audible tone will be heard from the receiver whenever any of the fan light or any other function buttons are pressed A LIGHT Functi...

Страница 10: ...ed as follows The uplight and downlight can be operated independently Press the Select button to change between downlight uplight fan operation When the downlight symbol glows on the LCD panel you have control of the down light When the uplight symbol glows on the LCD panel you have control of the uplight NOTE The Light On Off button features a soft on soft off feature that ramps the downlight dow...

Страница 11: ...t setting The Sleep icon will be seen on the LCD panel indicating Sleep mode If the fan is already on then it will decrease from its current setting If the fan is off it will start from fan setting 3 medium and decrease from there Once the Sleep function is activated the fan speed can be increased or lowered using the Up Down Arrow buttons without disabling the Sleep function The fan will continue...

Страница 12: ...amage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or damage to your remote control while in your possession ...

Отзывы: