This 22 gauge Blue wire is a
500mA Negative output,
which has the same
operation as the
12 gauge Blue
Ignition output.
NOTE: If an
additional Acc-
essory output is
needed, use the
programmable
built-in relay (Yellow/Green wire).
22 Gauge Blue Wire:
500mA ( - ) Ignition Output
Connection If Needed.
Wiring Connections - 12 Wire Harness
Red Wire
Green Wire
Blue Wire
To Additional
Ignition Circuit
Fused
constant
12 Volts
Optional
Relay
85
86
87a
87
30
To Additional
Starter Circuit
Optional
Relay
Fused
constant
12 Volts
85
86
87a
87
30
Red
3-pin
Harness
20-Gauge Gray Wire:
is NOT Used.
20-Gauge Brown Wire:
is NOT Used.
NOTE: On the 12
Wire Harness, the
19
10
Of the five Programmable Features, four are strictly “installation”-related, and one is “op-
erational” in nature. Installation-related features adapt the unit to certain vehicle situa-
tions; these are to be utilized at the time of the installation only.
Only Features
#
1 has a “daily use” benefit to the vehicle operator:
About the Programmable Features
Exiting Programming Mode:
Simply allow the unit to time out of Features Programming Mode by not perform-
ing any programming actions for 15 seconds; or, turn the ignition “On” to immediately
exit the programming mode.
The unit indicates its exit from Features Programming Mode with 2 short and 1
long Status Lights flashes and the parking lights turning off.
•
Feature
#
2 is “Starter Cranking Time”,
which sets the base starter cranking time
for the Smart Start voltage sensing engine detection method (page 34). When using
Smart Start, a longer starter cranking time may be used for engines which do not start on
the first remote start attempt. Programming choices are: .5 second (1 brake press, the
default setting); .75 second (2 brake presses); 1.25 second (3 brake presses); and 1.5
•
Feature
#
1 is “Engine Running Time”
. When it remotely starts the engine, the
run time before automatic shut-off is adjustable. A 10 minute run time is the factory
setting, with options of 20, 30 or 40 minutes. When programming press the brake pedal
1 time for the default-set 10 minute run time; or press the brake 2 times for 20 minutes;