Tightening torque: 16.3Nm / 12ft.lbs
tape
4. Connect the wiper to the ship’s electrical installation; see the diagram
above (or refer to paragraph 9.2 for full details on the wiring). Use a cable
with 5 wires with diameter of at least 1½ mm
2
(16 g) up to a maximum
length of 10 m. Use larger diameters when using longer cables.
5. Fit a slow blow fuse of 6A(12Volt), 4A (24 Volt) in the main cable.
6. Connect the switch to the wiper (refer to that specific manual for
installation).
3.4 Final installation
7. Switch on the power and test the motor briefly. Wait until the motor stops
after turning off the switch. The motor will be in park position. The
standard park position is shown in the figure under point 8.
Hint!
If you have doubts regarding the park position,
make a vane with tape to simulate the position of
the arms.
Attention!
The 232BD is suitable for wiper arms model PU up to
750 mm and wiper blades up to 800 mm.
8. Place the wiper arm with the blade on the
shafts. Fasten the nuts loosely onto the shafts.
9
!
!