Exalt Communications, Inc.
r-series
Installation and Management Manual
5000007 (ETSI)
12
2007-02-12 (draft)
L
= Total transmission system losses of all elements between the radio’s RF
connector and the antenna’s RF connector (all cables, connectors,
lightning suppressors), in dB, as specified or measured between 5250
and 5350 MHz
For the 5250–5350 MHz band, the maximum EIRP allowed for this device is 30dBm. The
maximum output power of the radio shall never 13dBm.
The professional installer is responsible to ensure that RF output power is properly adjusted so
that it does not exceed the regulatory limit of these conditions.
Canada Compliance
The EX-5r Series operates under RSS-210 of Industry Canada regulations. The EX-4.9r
Seriesoperates under RSS-111 of Industry Canada regulations. Operation is subject to the
following conditions, unless express permission is granted by Industry Canada to operate in a
different manner:
•
External amplifiers cannot be used to boost the power or to overcome transmission system
losses, unless the specific amplifier/cable/antenna combination is expressly authorized by
Industry Canada.
•
Cross-border transmissions are expressly prohibited, except with written permission from
both Industry Canada and the governing body of the neighboring country (FCC for USA)
•
Only parabolic dish antennas or directional flat-panel antennas may be used. No other types
of antennas (omni-directional, yagi, and so on) are authorized. Parabolic dishes of either grid
or solid type are allowed. Maximum gain of each type of antenna allowed is:
¶
Parabolic dish: 37.5 dBi (6'/1.8m diameter)
¶
Directional flat panel: 28 dBi (~2'/61cm square)
A complete list of allowed antennas can be found in Industry Canada (IC), Canada on page v.
IC (Canada) EIRP
EX-4.9r Series IC (Canada) EIRP
For the EX-4.9i model, within the 4940–4990 MHz band, the maximum EIRP allowed is
+50dBm. The maximum output power of the radio shall never 24dBm.
For the EX-4.9i models, the transmit power must be reduced from maximum (+20dBm for
40MHz BW, +24dBm for 20MHz BW, +22dBm for 10MHz) by 1 dB for every 1dB that the
antenna gain exceeds 26dBi (including transmission system losses).
The professional installer is responsible to ensure that RF output power is properly adjusted so
that it does not exceed the regulatory limit of these conditions.
EX-5r Series IC (Canada) EIRP
Within the 5725–5850 MHz band, the maximum EIRP allowed is 61.5dBm. The maximum
output power of the radio shall never 24dBm.