3 Function
specification
3/16
3.9.2
P1 I-start: Ignition current
The ignition current is infinitely adjustable from 0% to 100% of the main current AMP (G1) (works
setting 30%)
Function Setting
Increase ignition current
Reduce ignition current
(search arc in 0% position)
3.9.3
P2 t-UP: Up-slope time
Current increase from the ignition current I
start
to the value of the main current AMP (G1) infinitely
adjustable from 0 to 5 sec (works setting 0.1 sec).
Function Setting
Increase Up-slope time
Reduce Up-slope time
3.9.4
JP5: Switching between normal or tapping operation
(works setting tapping operation)
Operating mode configuration
Setting
Tapping released
:
JP5
Tapping blocked
JP5
3.9.5
S3 tPulse and S4 tPause: TIG pulses, pulse and break time adjustment
Switch position
0/1 2/3 4/5 6/7 8/9 A/B C/D E/F
Time [sec]
0.1 0.3 0.5 0.7 0.9 1.1 1.3 1.5
Table 1: Coding switch
3.9.5.1 S3 tPulse: Pulse time (works setting 0.3 sec)
The pulse time can be adjusted from 0.1 sec to 1.5 sec in 0.2 sec steps on coding switch S3 (see
table 1)
3.9.5.2 S4 tPause: Pulse break (works setting 0.3 sec)
The pulse break can be adjusted from 0.1 sec to 1.5 sec in 0.2 sec steps on coding switch S4 (see
table 1)
3.9.5.3 Example
of
settings for the pulse time and pulse break
Requirement: The pulse time should be 1.1 sec and the break time 0.5 sec:
•
Coding switch S3 must be switched to position A or B,
•
Coding switch S4 must be switched to position 4 or 5,
Содержание TRITON 260 DC
Страница 57: ...10 Circuit diagram 10 1 10 1 TRITON 260 Circuit diagrams are also in the machine...
Страница 58: ...10 Circuit diagram 10 2...
Страница 59: ...10 Circuit diagram 10 3 10 2 TRITON 360 500 Circuit diagrams are also in the machine...
Страница 60: ...10 Circuit diagram 10 4...
Страница 61: ...10 Circuit diagram 10 5...