Rectifying faults
Resetting welding parameters to the factory settings
099-007021-EW501
29.07.2015
99
7.4
Resetting welding parameters to the factory settings
All customised welding parameters that are stored will be replaced by the factory settings.
ENTER
+
EXIT
NAVIGATION
l
0
Figure 7-1
Display
Setting/selection
Exit the menu
Exit
Service menu
Modifications to the service menu may only be carried out by authorised maintenance
staff!
Reset (reset to factory settings)
• off = aus (factory setting)
• CFG = Reset the values in the machine configuration menu
• CPL = Complete reset of all values and settings
The reset is performed when leaving the menu (EXIT).
Switch off
Switching off machine function
Reset machine configuration
Resetting the values in the machine configuration menu
Complete reset
Complete reset of all values and settings by the factory settings