Design and function
TIG Synergic operating principle
099-007021-EW501
29.07.2015
43
5.11.1 Synergic parameter setting in the functional sequence
When setting the welding current, all the necessary welding parameters are adjusted automatically during
the functional sequence - See 4.3.1 Function sequence chapter with the exception of the gas pre-flow
time. These welding parameters can also be set in the conventional way if required (regardless of the
welding current) - See 5.11.2 Conventional parameter setting in the functional sequence chapter.
Figure 5-14
5.11.2 Conventional parameter setting in the functional sequence
All welding parameters in the functional sequence can also be adjusted, regardless of the welding current
set. This means that if the welding current is changed, the values for the down slope time or gas post-flow
time remain unchanged, for example. The welding task still needs to be selected as before using the
three basic parameters of tungsten electrode diameter, material type and seam type.
Figure 5-15
The parameters for the ignition, secondary and end currents can be set and displayed as
percentage values or absolute values- See 5.19 Machine configuration menu chapter.
Содержание Tetrix 150 Synergic Plasma
Страница 16: ...Machine description Front view 16 099 007021 EW501 29 07 2015 4 Machine description 4 1 Front view Figure 4 1...
Страница 18: ...Machine description Rear view 18 099 007021 EW501 29 07 2015 4 2 Rear view Figure 4 2...
Страница 32: ...Design and function Plasma welding 32 099 007021 EW501 29 07 2015 Figure 5 7...
Страница 109: ...Appendix B Overview of EWM branches 099 007021 EW501 29 07 2015 109 11 Appendix B 11 1 Overview of EWM branches...