Design and function
TIG Synergic operating principle
099-007021-EW501
29.07.2015
57
5.11.11 Pulse variants
The machines have an integrated pulse device.
With pulses, the machine switches back and forth between the pulse current (main current) and
pause current (secondary current).
Pulses (thermal pulses)
With thermal pulses, the pulse and pause times (frequency up to 200 Hz) and the pulse edges (ts1 and
ts2) are entered in seconds on the control.
Figure 5-28
Operating
element
Action
Result
Display
Select TIG pulses function
Signal light comes on in green
-
Select pulse time "t1"
LED "Pulse time" comes on
Set pulse time "t1"
Select pause time "t2"
LED "Pulse pause time" comes on
Set pause time "t2"
2 s
Select slope times "ts1 and ts2"
Set slope time "ts1"
Change between slope times "ts1 and ts2"
Set slope time "ts2"