![EWM Taurus Synergic drive 200C Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/ewm/taurus-synergic-drive-200c/taurus-synergic-drive-200c_operating-instructions-manual_2448255038.webp)
Design and function
MIG/MAG welding
38
099-005211-EW501
23.08.2010
Operating
element
Action Result
Wire
Gas
Material
JOB-
LIST
1 x
Select JOB list
(LED
Wire
Gas
Material
is on)
m/min
Set JOB number.
Wait 3s until the setting has been adopted.
Operating mode changeover switch
Switching between non-latched and latched operation or between
special non-latched and special latched.
Non-latched
operation
Non-latched, special non-latched and MIG spots can be
selected using the power source control.
Latched
operation
Latched and special latched can be selected using the power
source control.
To change the factory settings, refer to the "Advanced settings> P18"
section in the welding machine operating instructions.
n x
Operating mode button
The signal light indicates the selected operating mode.
Non-latched operation preselected at the wire feed unit:
Non-latched
operation
Green Special non-latched operation
Red
Spot operating mode
Latched operation preselected at the wire feed unit:
Latched
operation
Special
latched
operation
To change the factory settings, refer to the "Advanced settings> P18"
section.
m/min
0,5
1
1,5
2
2,5
3
3,5
4
5
6
7 8 9 10
11
12
13
14
15
16
18
20
22
24
Rotary dial, wire speed
Wire speed setting (welding performance, one-dial operation)
0.5 to 24 m/min
+
-
V +
-
0
1
1
2
2
3
3
7
7
5
5
10
10
Arc length correction rotary dial
Arc length correction from -10 V to +10 V in 24 increments. Correction
depends on the values preselected on the power source.
- +
DYN
Select dynamic setting.
(Signal light
DYN
is on)
m/min
Set dynamic. (Setting range 40 to -40)
40:
Arc hard and narrow.
-40:
Arc soft and wide.