Rectifying faults
General operating problems
099-005211-EW501
23.08.2010
51
7.2.2
Resetting all JOBs
JOB-
LIST
JOB-
LIST
m /m in
Figure 7-2
Display Setting/selection
Reset to factory settings
The RESET will be done after pressing the button.
The menu will be ended when no changes are done after 3 sec.
7.3
General operating problems
7.3.1
Interface for mechanised welding
WARNING
No function of the external shut-down devices (emergency stop switch)!
If the emergency stop circuit has been realised using an external shut-down device via
the interface for mechanised welding, the device must be set for this setup. If this is not
observed, the power source will ignore the external shut-down devices and will not shut
down!
• Disconnect jumper 1 on PCB T320/1 (Tetrix) or M320/1 (Phoenix / alpha Q)!