Machine description – quick overview
Machine control – Operating elements
20
099-005211-EW501
23.08.2010
4.3
Machine control – Operating elements
0
1
1
2
2
3
3
7
7
5
5
10
10
0,5
1
1,5
2
2,5
3
3,5
4
5
6
7 8 9 10
11
12
13
14
15
16
18
20
22
24
m/min
S
Taurus Synergic
4
3
2
1
Figure 4-7
Item Symbol Description
0
Rotary dial, wire speed
Wire speed setting (welding performance, one-dial operation)
Limits for the setting are defined by the JOB selected on the power source.
0.5 to 4 m/min:
In increments of 0.5 m/min
4 to 16 m/min:
In increments of 1 m/min
1
0,5
1
1,5
2
2,5
3
3,5
4
5
6
7 8 9 10 11
12
13
14
15
16
18
20
22
24
m/min
16 to 24 m/min:
In increments of 2 m/min
2
Ready for operation signal light
Signal light on when the machine is switched on and ready for operation
3
Operating mode changeover switch
Switching between non-latched and latched operation or between special non-latched
and special latched.
Non-latched
operation
Non-latched, special non-latched and MIG spots can be selected using the
power
source
control.
Latched
operation
Latched and special latched can be selected using the power source control.
To change the factory settings, refer to the "Advanced settings> P18" section in the
welding machine operating instructions.
4
+
-
V +
-
0
1
1
2
2
3
3
7
7
5
5
10
10
Arc length correction rotary dial
Arc length correction from -10 V to +10 V.
Correction depends on the values preselected on the power source.