Design and function
MIG/MAG welding
52
099-005444-EW501
17.03.2015
Non-latched mode
Figure 5-21
Step 1
• Press and hold torch trigger.
• Shielding gas is expelled (gas pre-flows).
• Wire feed motor runs at “creep speed”.
• Arc ignites after
the wire electrode makes contact with the workpiece; welding current flows.
• Change over to pre-selected wire speed.
Step 2
• Release torch trigger.
• WF motor stops.
• Arc is extinguished after the preselected wire burn-back time expires.
• Gas post-flow time elapses.