Design and function
Special parameters (advanced settings)
86
099-005444-EW501
17.03.2015
Display
Setting/selection
Program selection with standard torch trigger
0 = no program selection (Ex works)
1 = program selection possible
Mean value display for super pulses
0 =
Function switched off
1 =
Function switched on (factory setting)
Predefined execution of the pulsed arc welding process in the PA program
0 =
Predefined execution of the pulsed arc welding process in the PA program is
disabled.
1 =
If the superPuls and welding process switching functions are available and
activated, the pulsed arc welding process is always executed in the main
program PA (ex factory).
Predefined absolute value for relative programs
Start program (P
START
), down-slope program (P
B
) and end program (P
END
) can be set
relative to the main program (P
A
) or in an absolute manner, as desired.
0 =
Relative parameter setting (ex factory)
1 =
Absolute parameter setting
5.17.1.1 Reset to factory settings
All special parameters saved by the user will be overwritten by the factory settings!
Operating
element
Action
Result
Switch off welding machine
Keep the button pressed
Switch on welding machine
Release the button, wait about 3 seconds
Switch off welding machine and restart in order to put the changes into
effect
Содержание Taurus 355 Synergic S HP MM TKW
Страница 18: ...Machine description quick overview Rear view 18 099 005444 EW501 17 03 2015 4 2 Rear view Figure 4 2...
Страница 113: ...Appendix A JOB List 099 005444 EW501 17 03 2015 113 11 Appendix A 11 1 JOB List Figure 11 1...
Страница 114: ...Appendix B Overview of EWM branches 114 099 005444 EW501 17 03 2015 12 Appendix B 12 1 Overview of EWM branches...