Design and function
Special parameters (advanced settings)
92
099-005444-EW501
17.03.2015
Latched special tapping time setting (P11)
The tapping time for changing over between the main program and reduced main program can be set in
three levels.
0 = no tapping
1 = 320ms (factory setting)
2 = 640ms
JOB list switching (P12)
Value Designation
Explanation
0
Task-oriented
JOB list
The JOB numbers are sorted by welding wires and shielding gases.
JOB numbers may be skipped during selection where relevant.
1
Actual JOB list
JOB numbers correspond to the actual memory cells. Each JOB can be
selected; no memory cells are skipped during selection.
2
Actual JOB list,
JOB changeover active
As for the actual JOB list. JOB changeover is also possible with
accessory components, such as the PowerControl 2 torch.
Creating user-defined JOB lists
A consecutive memory range where accessories such as the POWERCONTROL 2 torch can be
used to switch between JOBs will be created.
• Set special parameter P12 to "2".
• Set "Program or Up/Down function" changeover switch to "Up/Down" position.
• Select an existing JOB which is closest to the required result.
• Copy JOB to one or more target JOB numbers.
If any JOB parameters need to be changed, select the target JOBs in sequence and change the
parameters individually.
• Set special parameter P13 to the lower limit and
• Set special parameter P14 to the upper limit of the target JOBs.
• Set "Program or Up/Down function" changeover switch to "Program" position.
JOBs can be changed over in the specified range using the accessory component.