5.1.10 Expert menu (TIG)
The Expert menu has adjustable parameters stored that don’t require regular setting. The number of pa-
rameters shown may be limited, e.g. if a function is deactivated.
ENTER
EXIT
Figure 5-23
Display
Setting/selection
Expert menu
Gas pre-flow time
Ignition current
Setting range in percent: depending on main current
Setting range, absolute: Imin to Imax.
Slope time (main current to secondary current)
Slope time (main current to secondary current)
Slope time (main current to secondary current)
End-crater current
Setting range in percent: depending on main current
Setting range, absolute: Imin to Imax.