5.1.6.1 Mains configuration
The machine may only be connected to a one-phase system with two conductors and an earthed
neutral conductor.
Figure 5-6
Legend
Item
Designation
Colour code
L
Outer conductor
brown
N
Neutral conductor
blue
PE
Protective conductor
green-yellow
• Insert mains plug of the switched-off machine into the appropriate socket.
5.1.7
Shielding gas supply (shielding gas cylinder for welding machine)
WARNING
Risk of injury due to improper handling of shielding gas cylinders!
Improper handling and insufficient securing of shielding gas cylinders
can cause serious injuries!
• Place shielding gas cylinder into the designated holder and secure with
fastening elements (chain/belt)!
• Attach the fastening elements within the upper half of the shielding gas
cylinder!
• The fastening elements must tightly enclose the shielding gas cylinder!
An unhindered shielding gas supply from the shielding gas cylinder to the welding torch is a
fundamental requirement for optimum welding results. In addition, a blocked shielding gas
supply may result in the welding torch being destroyed.
• Always re-fit the yellow protective cap when not using the shielding gas connection.
• All shielding gas connections must be gas tight.
5.1.7.1 Pressure regulator connection
Figure 5-7
Item Symbol
Description
0
1
Pressure regulator
2
Shielding gas cylinder