Design and function
MIG/MAG welding
099-005548-EW501
27.10.2017
33
Pay attention to the signal light for the polarity setting!
It may be necessary to change the welding current polarity depending on the JOB selected or the
welding process.
• Reconnect the polarity selction plug if necessary.
5.3.4
Welding task selection
The settings for the respective welding parameters are defined by the different JOBs. The right JOB can
be determined quickly with the JOB list
> see 11.1 chapter
.
3s
Figure 5-16
Validity of the settings.
Spot time, pause time and wire feed speed settings apply to all JOBs. Throttling effect/dynamics,
gas post-flow time, gas pre-flow time and wire burn-back correction are stored for each JOB
individually.
Changes are stored permanently in the JOB that is currently selected.
If required, these parameter values can be reset to the factory settings > see 7.3 chapter.
5.3.5
MIG/MAG operating point
5.3.5.1 Selecting the welding parameter display mode
The operating point (welding power) can be displayed or set as the welding current, material thickness or
wire speed.
Figure 5-17