Design and function
Shielding gas supply
32
099-005084-EW501
22.09.2011
Figure 5-7
Item Symbol Description
0
1
Pressure regulator
2
Shielding gas cylinder
3
Output side of the pressure regulator
4
Cylinder valve
• Tighten the pressure regulator screw connection on the gas bottle valve to be gas-tight.
• Screw gas hose connection crown nut onto the output side of the pressure regulator.
5.8.2
Setting the shielding gas quantity
Welding process
Recommended shielding gas quantity
MAG welding
Wire diameter x 11.5 = l/min
MIG brazing
Wire diameter x 11.5 = l/min
MIG welding (aluminium)
Wire diameter x 13.5 = l/min (100 % argon)
TIG
Gas nozzle diameter in mm corresponds to l/min gas throughput
Helium-rich gas mixtures require a higher gas volume!
The table below can be used to correct the gas volume calculated where necessary:
Shielding gas
Factor
75% Ar/25% He
1.14
50% Ar/50% He
1.35
25% Ar/75% He
1.75
100% He
3.16
NOTE
Incorrect shielding gas setting!
If the shielding gas setting is too low or too high, this can introduce air to the weld pool
and may cause pores to form.
• Adjust the shielding gas quantity to suit the welding task!