Design and function
Mains connection
24
099-005084-EW501
22.09.2011
5.5
Mains connection
DANGER
Hazard caused by improper mains connection!
An improper mains connection can cause injuries or damage property!
• Only use machine with a plug socket that has a correctly fitted protective conductor.
• If a mains plug must be fitted, this may only be carried out by an electrician in accordance
with the relevant national provisions or regulations (any phase sequence for three-phase
machines)!
• Mains plug, socket and lead must be checked regularly by an electrician!
• When operating the generator always ensure it is earthed as stated in the operating
instructions. The resulting network has to be suitable for operating devices according to
protection class 1.
CAUTION
Operating voltage - mains voltage!
The operating voltage shown on the rating plate must be consistent with the mains
voltage, in order to avoid damage to the machine!
• For mains fuse protection, please refer to the “Technical data” chapter!
NOTE
Before connecting to the mains network and before disconnecting from the mains
network:
• Move the mains switch to the "0" position
5.6
Mira 151
NOTE
The machine may be connected and operated on all TN or TT networks with a neutral
conductor and a protective conductor.
L1
N
PE
Figure 5-1
Legend
Item Designation
Colour
code
L1 Outer
conductor
brown
N Neutral
conductor
blue
PE Protective
conductor
green-yellow
• Insert mains plug of the switched-off machine into the appropriate socket.