Telesm a r t T XG
Retrieving memory positions
• To retrieve a memory position, press the relevant button
, or on the operating element.
Hold the button depressed until the actuators have moved
into position.
7.4.2.4
Master-Slave Operation
Buttons and on the operating element can be used to
move master and slave independend of each other.
Fig. 14
P2
P1
M
P3
• button The actuator extends.
• button The actuator retracts.
NOTE
If the memory positions become inaccurate over the course of time,
repeat the initialsation run.
CAUTION
n case of an master without “parallel operation” and/or and/or
“memory” the actuators should not be controled at the same time.
The control may be overloaded.
7.5 Disengagement in
case of emergency
In hazardous situations, all movements of the device must
be stopped as quickly as possible and the power supply
must be turned off.
Procedure in hazardous situations:
1. Immediately engage emergency shut-off, if present, or
cut off power for actuator (⮑ 7.5.1 Shut dawn, page 22).
2. Evacuate people from the hazard zone, initiate first aid
measures.
3. Notify doctor and fire department, if necessary.
4. Notify responsible person on-site.
5. Keep access paths open for rescue vehicles. Order spe-
cialized staff to repair malfunction.
6. Based on severity of emergency, notify the authorities if
necessary.
7. Order specialized staff to repair malfunction.
WARNING
Do not restart until all persons are outside the hazard zone.
Check the device and application that uses the device prior to
restarting the operation and ensure that all safety equipment is
installed and fully functional.
8. Check the device and application that uses the device
prior to restarting the operation and ensure that all safety
equipment is installed and fully functional.
NOTE
The telescopic pillar TXG does not have its own on/off switch and
must be disconnected from the mains supply. Only this measure
will de-energize the device.
NOTE
The application doing further processing must provide an
emergency stop switch or a seperation from the mains supply on
all poles.
7.5.1 Shut down TXG10 (slave or
standalone)
Pull the power line plug DIN-8 out of the used control unit or
the corresponding master actuator (⮑ fig. 15).
Fig. 15
7.5.2 Shut down TXG (all types except
TXG10)
Pull the power line plug out of the power source.