6.0 In s ta llation an d fir st o p eration
6.4 Connect to the
control unit
NOTE
This section is applicable for slave types of TXG (TXG10) without
integrated control unit and power supply which can be used with a
separate external control unit.
All control units which are not approved for the TXG devices
by Ewellix are treated as third party controls.
CAUTION
Material damage due to third-party control unit
The use of a third-party control unit may lead to material damage.
In conjunction with the use of a thir d-party control unit, the
manufac-turer does not assume any liability for damage that may
be caused.
Therefore:
• It is recommended to use the Ewellix control unit from the manu-
facturer.
• When using the third-party control unit, the requirements stipu-
lated for the third-party control unit must be adhered to (⮑ 4.2.1
Requirements for third party control unit, page 11).
NOTE
A low-voltage plug connects the device to an external control unit.
Adhere to the instructions of the operating manual of the Ewellix
Control unit during the connection process.
The low-voltage plug has been fitted with a DIN-8 plug.
Connec the external control unit o the eight-pin socket
marked “Slave” (⮑ fig. 3 on page 11) using the connection
cable.
Ensure that the plug is correctly seated. The nose of the
plug must face upwards (⮑ fig. 6).
Fig. 6
NOTE
Please adhere also to the instructions of the control unit
regarding connection.
6.5 Connection to
operating element
WARNING
Risk of injury and material damage due to third party
operating element
The use of a third party operating element may lead to significant
injuries or material damage.
In conjunction with the use of a third-party operating element, the
manufacturer does not assume any liability for damage that may be
caused.
Therefore:
• Only use the manufacturer’s Ewellix operating element. In case of
using additional equipment which has not protection class II, the
mounting plate must be connected to the earth wire
6.5.1 Connect TXG10 (stand alone) to
operation element
NOTE
The device is connected to the operating element via an external
control (⮑ Separate operating manual of the control and the
operating element).
6.5.2 Connect TXG (all types except
TXG10) to operating element
NOTE
The device is connected directly to an operating element.
Adhere to the operating instructions for the operating elements in
regard to the connection (⮑ Separate oprating manual).
The operating element is fitted into the socket 3 (⮑ fig. 3
on page 11).
Fig. 7
Ensure that the nose of the plug engages correctly ("click").