14
CA S M
NOTE
Information concerning the dimensions of the drill holes
for fastening bolts can be found in the respective data sheets.
(⮑ 11 Appendix, page 28).
WARNING
Risk of injury and material damage due to insufficient
fastening!
Only use fastening bolts and secure them adequately. Do not
use screws to install. Never loosen or remove screws on
the actuator.
6. During installation, ensure that the applied force is al-
ways directed on the center of the actuator.
WARNING
Risk of injury and material damage due to incorrect
installation!
During installation, do not subject the actuator to side-impact or
to turning forces.
7. Ensure that the linear actuator is not impacted in its
movement over the entire stroke area. Consider collision
tests of the application.
8. Ensure that the installation requirements of the options
have been adhered to (⮑ Chapter “Requirements
Concerning the Installation of the Actuators with
Options”).
9. Affix prohibition and warning labels for the application
onto the linear actuator, if necessary (⮑ 2.5.1 Warning
labels, page 7).
10. Start set-up for 10 reference travel with limited load and
speed:
CASM 32: 0,1 x 10–3 J maximum
CASM 40: 0,2 x 10–3 J maximum
CASM 63: 0,4 x 10–3 J maximum
NOTICE
Do not reach the mechanical limit of the drive during operation.
Doing so will result in irreversible damage to the drive.