18
CA S M
7.3.5 Adapter kit installation
NOTE
The relevant seal must always be fitted between all components
to ensure the requisite degree of IP protection.
Fig.9
NOTE
For the following steps, check the required screw size and the
tightening torques using the values indicated in the table 2.
Step 1
Mount the coupling housing (K) to the linear unit (LE) by in-
serting the square seal with the cut-out (D1) between the
two components and tightening the housing using four Allen
screws (S1). (⮑ Foot mounting option 7.5.5.1)
Step 2
Mount the motor flange (MF) to the coupling housing (K) by
inserting the circular seal (D2) in between them. Make sure
that the coupling is positioned according to table 4 for the
configuration without the foot mounting kit or table 5 when
using the foot mounting kit. Tighten the screws (S2) accord-
ing to table 2.
Step 3
Mount the motor flange (MF) to the motor (M) by inserting
the seal (D3) in between and using the four screws (S3)
(fig. 9) to finish the installation.
D1
D1
D2
D3
S2
S1
K
LE
FB
S3
M
MF
D1
D2
D3
S2
S1
K
LE
S3
M
MF
7.5.5.1 Foot mounting option
Fitting the foot mounting
First fit the foot mounting (FB) to the linear unit (LE) and then
the coupling housing (K). Insert one square seal with cut-out
(D1) between each of the components, and secure the hous-
ing (K) using four Allen screws (S1) to the linear unit (LE).
Continue with Step 2 as described in chapter 7.3.5.
Fig.10