Aux_TC_DLY
Here you set the delay in frames which should be applied to the auxiliary time
code inserter.
Ins_CtrlA
With this item you select how the inserter presets are controlled: Manually
(manual), via GPI-triggers (GPI-A, GPI-B or GPI-C), via changes of the SD aspect
ratio (SD_AR) or the HD aspect ratio (S2016). Can be set to Follow, in which case
this setting will automatically follow the active preset. Default is Manual.
Ins_Prst_ActA
With this item you can manually change the currently active preset of Channel A
when in transparent mode. Can be any preset between 1 and 16. By default it is
set to 1. All menu settings that are preceded with a ‘#Ins’ prefix are part of the
preset.
Ins_Prst_EditA
Here you can select which of the 16 selectable presets you want to edit when in
a transparent mode. Changing this will not change the active preset, unless the
currently active preset is the same you are going to edit. All menu settings that
are preceded with a ‘#Ins’-prefix are part of the preset.
#VI-InsertA
You can turn VI insertion on or off for Channel A. Default is Off.
#VI-DataA
With the #VI-InsertA setting set to On, you can select VI values with this setting,
which you want to be inserted. possible are all VI values from 4:3_0 through 4:3_
7 and the settings from 16:9_0 through 16:9_7. Default is 4:3_0.
#WSS-InsertA
You can choose which type of WSS data you want to insert with this setting, or
switch WSS insertion entirely off (default value). You can set it to Standard or
Extended.
With the #WSS-InsertA setting set to Extended, you can select WSS extended values from
the #VI-DataA setting, which you want to be inserted. Possible VI settings are 4:3_0 through
4:3_7 and the settings 16:9_0 through 16:9_7. Default is 4:3_0.
#WSS-StndA
With the #WSS-InsertA setting set to Standard, you can select WSS standard
values with this setting, which you want to be inserted. Possible are all WSS
values from 1_vid through 8_vid and the settings from 1_flm through 8_flm.
Default is 1_vid.
#WSS-ExtndA
With the #VI-InsertA setting set to Extended, you can select VI values with this
setting, which you want to be inserted. Possible WSS values are 4:3_0 through
4:3_7 and the settings 16:9_0 through 16:9_7. Default is 4:3_0.
#S2016-InsertA
You can turn S2016 (AFD) insertion on or off for Channel A. Default is Off.
#S2016-DataA
With the #S2016-InsertA setting set to on, you can select AFD values with this
setting, which you want to be inserted. possible are all AFD values from AFD0
through AFD15.
#OP47-SDP-Emb_A With this setting you set in which line the OP47 data should be inserted. Can be
any line between line 8 and line 16. Can also be switched off (causing the OP47
data to not be inserted at all).
#CC_Ena_A
This setting sets the Closed Captioning transparency for Channel A On or Off.
Default is Off.
26