![EVS Synapse GXG100 Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/evs/synapse-gxg100/synapse-gxg100_installation-and-operation-manual_2447679055.webp)
Example 1: Two Pools in Binary Mode
To control the up converter presets using Pool A (Up_CtrlA set to GPI-A) and the output mode setting
using Pool B (Out-mode-Ctrl set to GPI-B), with both pools working in priority mode, the GPIs have to be
set up as follows:
•
Set GPI_A-Mode to Prio
•
Set Contact_1 to GPI_A
•
Set Contact_2 to GPI_A
•
Set Contact_3 to GPI_A
•
Set Contact_4 to GPI_A
•
Set GPI_B-Mode to Prio
•
Set Contact_5 to GPI_B
Pool A now consists of GPI 1, GPI 2, GPI 3 and GPI 4 in priority mode, controlling the Up converter preset.
Pool B consists only of GPI 5 (also in priority mode), controlling the Output mode setting.
Pool A now works as follows:
Contact_1
Status
Contact_2
Status
Contact_3
Status
Contact_4
Status
GPI_A
Value
0
0
0
0
Up-conv Preset 1
1
0
0
0
Up-conv Preset 1
0
1
0
0
Up-conv Preset 2
0
0
1
0
Up-conv Preset 3
0
0
0
1
Up-conv Preset 4
0
1
1
0
Up-conv Preset 3 (because
highest takes priority)
1
1
1
1
Up-conv Preset 4 (because
highest takes priority)
Table 5. Pool value in priority mode
Pool B now works as follows:
Contact 5 Status GPI_BValue
0
A out only
1
B out only
Table 6. Pool value in priority mode
INSTALLATION AND OPERATION MANUAL
Synapse GXG100 | Appendix 1: GPIs Explained |
47