HDSD9545DLY - PRO Profanity Bypass Delay Manual
TECHNICAL DESCRIPTION
Revision
1.3.7
Page 4-3
4.1.10. Electrical
Voltage:
Auto ranging 100
⇔
240 Volts AC, 50/60 Hz – dual redundant power supplies
Fuse Rating:
250 V, 1amp time delay
Power:
40
watts
Safety:
TüV Listed, complies with EU safety directives
EMI/RFI:
Complies with FCC Part 15 Class A regulations
Complies with EU EMC directive
4.1.11. Physical
Dimensions:
19“ W x 3.5” H x 7.75” D.
(483mm W x 89mm H x 196mm D)
Weight:
8 lbs. (3.5Kg)
4.2.
SERVICING INSTRUCTIONS
CAUTION – These servicing instructions are for use by qualified service
personnel only. To reduce risk of electric shock do not perform any
servicing instructions in this section of the manual unless you are qualified
to do so.
Make sure that both power cords are disconnected before opening the top
cover of the unit.
4.2.1. Changing the Fuses
The fuse holder is located inside the power entry module. To change the fuses, disconnect the line cord
from the power entry module and pull out the fuse holder from the power entry module using a small
screwdriver. The fuse holder contains two fuses, one for the line and one for the neutral side of the mains
connection. Pull out the blown fuse and place a fuse of the correct value in its place. Use time delay 5 x
20 mm fuses rated for 250 Volts with a current rating of 1 amp. Carefully reinsert the fuse holder into the
power entry module.
Check that the line fuse is rated for the correct value marked on the rear
panel. Never replace with a fuse of greater value.