SERIAL PROTOCOL
A6
Sense Generator Run/Hold
Returns 1 byte as defined below.
86
Select Generator Run/Hold
1 byte
Turns the Generator Hold On and
Off.
00 = Generator Hold
01 = Generator Run
A7
Sense Generator Jam Sync Mode
Returns 1 byte as defined below.
87
Select Generator Jam Sync Mode
1 byte
Selects the Generator Jam Sync
mode
00 = Generator Free Run (Jam Off)
01 = Continuous Jam Sync
02 = Momentary Jam Sync.
When Continuous Jam Sync mode is enabled, then generator time will be slaved to
the time code from the Reader. The Run/Hold, Drop Frame, and Colour Frame
modes of the generator are determined by the Reader time code. When Continuous
Jam Sync mode is terminated, the formatted Run/Hold, Drop Frame and Colour
Frame modes of the generator are resumed.
A8
Sense Generator No Code Jam
Returns 1 byte as defined below.
88
Select Generator No Code Jam
1 byte
Determines the behavior of the
Generator when it is in continuous
jam sync mode and there is no
incoming code to the reader.
00 = Hold
01 = Run
02 = Mute
89
Preset Generator Time
4 bytes
Presets the time code generator.
This command has no effect when
the generator is in continuous Jam
Sync mode. Expects four bytes of
time data in BCD format as shown
below.
10 Fr
1 Fr
10 Sec
1 sec
10 Min
1 Min
10 Hr
1 Hr
8A
Preset Generator User Bit Data
4 bytes
Presets the generator user bits.
This command has no effect when
the generator user bits are being
transferred from either the Reader
Time or User Bits. Expects four
bytes of user bit data in DATA
Format as shown below.
UB grp 2
UB grp 1
UB grp 4
UB grp 3
UB grp 6
UB grp 5
UB grp 8
UB grp 7
Содержание 8010TM
Страница 2: ...This page left intentionally blank ...
Страница 6: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 12: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 18: ...Model 8010TM SDI Time Code Master Manual Page 1 6 Revision 1 5 1 OVERVIEW This page left intentionally blank ...
Страница 20: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 30: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 68: ...Model 8010TM SDI Time Code Master Manual Page 3 38 Revision 1 5 1 OPERATION This page left intentionally blank ...
Страница 70: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 88: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...