Model 8010TM SDI Time Code Master Manual
OPERATION
Revision 1.5.1
Page 3-3
3.1.4. An Overview of the SHIFT Key Functions
When the
SHIFT
key is held down, the meanings of some of the keys are modified, gaining quick
access to a wider variety of functions. Following is a summary of the shifted key functions:
SHIFT+SETUP:
Enters the Engineering Setup menu system.
SHIFT+SELECT:
Resets the 8010TM to factory defaults when you are in the FACTORY
RESET menu item of the Engineering Setup Menu.
SHIFT+DISPLAY:
Displays the Jam Sync Offset, and Reader and Generator event registers.
3.1.5. Panel Lock Key functions
When the
DISPLAY
and
SHIFT
keys are held down at the same time, pressing the
SELECT
key will
lock the front panel. All front panel keys will be disabled and the front panel will display the message:
Panel lock on
When the front panel is locked, and the
DISPLAY
and
SHIFT
keys are held down at the same time,
pressing the
SELECT
key will unlock the front panel. All front panel keys will be enabled to their
normal functions and the front panel will display the message:
Panel lock off
3.1.6. An Overview of the Status Indicators
There are 8 status indicators located on the front panel that show operational status of the 8010TM at a
glance.
VITC GEN:
Indicates that the VITC keyer is enabled.
COL’R:
Indicates that the 8010TM is receiving a valid colour frame reference and is operating in
the colour frame mode.
BYPASS:
Indicates that 8010TM is operating in the Bypass Mode. The SDI video input is directly
connected to the SDI Bypass output and the 8010TM will have no effect on the video
signal.
VIDEO:
Indicates that input video is present. If it is blinking, it indicates a video signal is present
but the video standard is different from the
VIDEO TYPE
menu setting. (See section
3.7.1 for information on selecting the video type).
JAM:
Indicates that the generator is operating in the continuous Jam Sync Mode.
U/B TRANSFER:
Indicates that the Generator User Bits are being transferred from the active reader’s
time or user bits.
LTC READER :
Indicates that LTC reader is reading valid code.
VITC READER:
Indicates that VITC reader is reading valid code.
Содержание 8010TM
Страница 2: ...This page left intentionally blank ...
Страница 6: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 12: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 18: ...Model 8010TM SDI Time Code Master Manual Page 1 6 Revision 1 5 1 OVERVIEW This page left intentionally blank ...
Страница 20: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 30: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 68: ...Model 8010TM SDI Time Code Master Manual Page 3 38 Revision 1 5 1 OPERATION This page left intentionally blank ...
Страница 70: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 88: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...