3
Mounting the AC133
Note:
Ensure the unit is installed within transmission range of the gateway using the
test above.
The Wall Switch can be installed on the wall either by using the supplied double-sided
tapes or the screws:
1.
Using the double-sided tape: first peel one side of the tape and place the sticky
side onto the back of the Wall Switch. Then peel the other side of the tape and
attach the unit onto a proper location on the wall. There are 3 tapes in the package
and you can retain other 2 tapes for future use.
2.
Using the screws:
i.
Detach the rear cover by removing the front cover and then pressing the rear
cover latch (see item
in Product Overview).
ii.
Use the rear cover as a template to mark on the wall the positions of two
screws. The marks should be in horizontal positions and the distance
between the two marks is 60mm.
iii.
Drill the holes using an appropriate size drill bit. Insert the supplied plastic
wall plugs first for a cement wall. For a wooden wall the wall plugs would not
be needed.
iv.
Position the rear cover on the wall and turn the two screws into the wall (or
wall plugs). DO NOT fasten too tightly as the rear cover might be damaged.
Then replace the main body and the front cover.
60MM
Maintenance
1.
Do not put the unit in humid or dusty places or facing direct sunlight.
2.
Do not place the unit near combustible substances or any source of heat, e.g. fires,
radiators, boilers etc.
3.
The suitable ambient temperature for the unit is -10°C - +40°C.
Low Battery: The Wall Switch will inform the Gateway when its battery runs low. Also, if
the unit has completed binding with a Gateway and the front cover is detached, you
can see the LED flashes once when you press the ON/OFF Knob to indicate low
battery condition.
Troubleshooting
The troubleshooting table lists some possible causes and solutions. Please contact
your original retailer or nearest service center if the below solutions cannot solve your
problem.
Symptom
Possible Cause
Recommendation
Press Wall Switch, LED
illuminates, but the
receiver(s) have no
response
1.
Distance between the
Wall Switch and the
receiver(s) too far
2.
Battery running low
3.
Receivers did not learn
ID successfully
1.
Move closer to the receivers
2.
Replace new batteries
3.
Bind
with
Gateway
again
Содержание AC133