background image

 

20

 

No.  

Part 

Number 

Description 

U/M  QTY. 

EV311108  Wire Shelf, 18" x 24" w/Legs 

EA 

EV311090  Backplate 

EA 

EV311091  Storage Tank w/Closure 

EA 

EV308130  Male Connector 

EA 

5 + 

EV311092  Level Switch 

EA 

EV311094  Flow Monitor 

EA 

7 + 

EV311095  Delivery Pump  

EA 

8 + 

EV311096  Solenoid Valve 24VAC 

EA 

9 + 

EV311097  Air Filter 

EA 

10 

EV308921  Male Connector 

EA 

11 

01013841  Adapter, 3/8 Tube X 1/2" NPTE 

EA 

12 

EV311098  Valve, 3-Way 

EA 

13 

EV310610  Valve, Ball, 1/2" NPTE X 3/8" Tube  EA 

14 

01005637  Elbow, 3/8" NPTE X 3/8"  

EA 

15 

EV311099  Connector, 3/8 NPTI X 3/8 Tube 

EA 

16 

01005647  Elbow Union, 3/8" Tube 

EA 

17 

EV304131  Washer 5/16" 

EA 

18 

01004714  Plug In Elbow 

EA 

19 

01009649  Check Valve 

EA 

21 

00443629  Screw 1/4"-20  

EA 

22 

EV310929  Barb, ½" NPTE X ½" Hose 

EA 

23 

EV310313  Adapter Stem 

EA 

24 

EV311112  Divider 2-Way 3/8 Tube 

EA 

25 

00441632  Plug 3/8" NPTE 

EA 

27 

00223502  Coupling, 3/8” T x T 

EA 

26 

EV307218  Spacer Flat (Molded) 

EA 

28 

EV311100  Valve, Ball 3/8" NPTE X 1/4" Tube 

EA 

29 

EV310326  Tubing 3/8" OD Black 

FT 

32 

EV310923  Nipple, 3/8" X 1-1/4" 

EA 

33 

00443663  Elbow, 3/8” T x T 

EA 

34 

EV310428  Fitting Kit (2 per Kit) 

EA 

35 

EV310449  Hose,1/2" ID 

FT 

36 

EV309258  Clear Housing 

EA 

37 

EV307924  Oetiker Clamp 

EA 

38 

EV309349  Screw, #10-32 X 1-1/2" 

EA  12 

39 

EV309921  Cap Black w/Pressure relief 

EA 

40 

EV543000  Washer, #10 

EA  24 

41 +  EV309256  O-Ring 

EA 

42 

EV306014  Dual Mounting Bracket 

EA 

43 

EV309544  Mounting Bracket W/Screws 

EA 

45 

EV309391  RO Head Assembly, BW 

EA 

46 

EV309392  Carbon Filter Head Assembly, BW 

EA 

47 

EV303449  Screw, #10-32 X 5/16" 

EA  13 

48 

EV307850  Support Ring 

EA 

49 

EV310445  Label, Carbon Filter 

EA 

50 

EV310446  Label, RO Module 

EA 

51 

01010248  Adaptor, 3/8" Stem X 1/4" Tube 

EA 

53 

EV306996  Directional Arrow 

EA 

 

No.  

Part 

Number 

Description 

U/M  QTY. 

54 

EV306203  Screw, #10-32 X 5/16" 

EA 

55 +  01010332  Restrictor Assembly (capillary) 

EA 

56 

01000316  Terminal, Crimp-on Female 

EA 

57 

01009108  Terminal, Crimp-on Male 

EA 

58 

EV310404  Nipple Hex 

EA 

59 

EV307219  Spacer Plastic 

EA 

60 

01005646  Tee Union, 3/8" Tube 

EA 

61 +  EV310850  Pressure Gauge, 125 Psi 

EA 

62 

EV311101  Control w/Relay (01016156) & Cord  EA 

63 

EV309368  Ball Valve, 1/2" 

EA 

65 

00448687  Screw, #8-32 x 1/2" 

EA 

66 

EV300745  Washer, #8 

EA 

67 

A1256025  Nut, #8-32 

EA 

68 

EV311102  Clamp, 1" Diameter 

EA 

69 

EV300446  Screw, #8-32 X 5/8" 

EA 

72 

A1747007  Cable Tie 

EA 

74 

EV305586  Bracket Label 

EA 

80 

01005645  Adaptor, 3/8" NPTE x 3/8" Stem 

EA 

84 

EV310565  Label, ID 

EA 

85 

EV301316  Nut, #10-32 

EA  17 

86 

EV307224  Nut, 1/4-20 

EA 

87 

EV307150  U-Bolt 

EA 

88 

01015075  Needle Valve, 1/4" 

EA 

91 

EV306204  Washer, #10 Int. Tooth 

EA 

92 

EV310851  Tee 

EA 

93 

EV309348  Spacer Nylon 

EA 

95 +  01009647  Booster Pump 

EA 

96 

EV311109  Pump Bracket 

EA 

99 +  00955004  Cartridge Filter, 5 Micron 

EA 

106 +  EV960741  Carbon Cartridge, 6-TO, BW 

EA 

107 +  EV962703  RO Cartridge, 200 GPD, BW 

EA 

110 +  EV310362  Flow Restrictor (red plastic insert) 

EA 

112 

01014973  Accumulator Tank 

EA 

113 

EV310929  Barb Fitting, ½” NPTE x ½” Hose 

EA 

01012585 

Transformer, 120 VAC/24VAC – 75 
VA (models with 01009647 booster 
pump) 

* + 

01012956 

Transformer, 120 VAC/24VAC – 50 
VA (models without 01009647 
booster pump) 

EA 

EV305061  Tubing 1/4" OD Red 

FT 

EV309259  Pre-Filter Housing Wrench 

EA 

EV311117  Manual, MRS-200 

EA 

EV544700  Tubing, 1/4" OD Blue 

FT 

* + 

01016156  Relay, 24 Volt 

EA 

* Not Illustrated 
+ Recommended Spare Parts

 

Содержание MRS-200

Страница 1: ...1 Cat No EV311117 Rev B 11 6 03 DCO 7060 MODEL MRS 200 Reverse Osmosis Mineral Reduction System Installation and Start up Guide...

Страница 2: ...Installation 4 Cartridge Installation and Activation 10 Start Up and Blend Adjustment 10 Adjusting the Recovery 12 Operation 14 Maintenance 14 Performance Monitoring 16 TDS Measurement 16 Performance...

Страница 3: ...hlorine An activated carbon filter has been provided with this system to protect the reverse osmosis membrane from chlorine attack Influent chlorine should not exceed 3 mg L The MRS 200 System consist...

Страница 4: ...nd permit access for maintenance The system will weigh approximately 175 pounds when the storage tank is full 4 ____ Does the inlet water supply meet the requirements listed below 1 A minimum of 1 0 G...

Страница 5: ...nts Place the main unit on the shelf positioning the cartridge heads directly over the cutout area Insert a cable tie into one of the holes in the baseplate and through the wire slats in the shelf mak...

Страница 6: ...A MP S 2 INS E RT E LB OW FULLY 3 S LIDE LOCK ING CLIP UP TO S E CURE 1 S LIDE LOCK ING CLIP DOW N Figure 3 4 Water supplies with a dynamic operating pressure of 50 PSI or less require the use of the...

Страница 7: ...UMP 10 NUT 8 1 2 X 1 SPACER 4 10 X 1 1 2 SCREW 8 10 WASHER 16 MOUNTING PLATE Figure 4 5 Refer to Figure 5 for a sample general arrangement Use this as a guideline for determining valve location tubing...

Страница 8: ...ow control insert red plastic cylinder in small parts kit Press this insert into the red OD tubing Fig 6 Attach the end of the tubing with the flow control insert into the 3 8 stem x OD tube reducing...

Страница 9: ...lt receptacle at this time Figure 9 Figure 7 Figure 8 INLET WATER SUPPLY 50 PSIG MAX TO 120 VAC OUTLET A B C SOLENOID VALVE 1 5 2 4 3 IN A B C TO 120 VAC OUTLET SOLENOID VALVE IN COVER REMOVED 3 4 2 5...

Страница 10: ...ative solution from the RO cartridge and should not be consumed 6 If you are utilizing the capillary tubing assembly refer to the section titled Adjusting the Recovery for instructions Return to this...

Страница 11: ...to contain a range of TDS greater than what an RO system normally produces In those cases a filtered water blend valve has been provided to blend in filtered not RO treated water to attain a specific...

Страница 12: ...product flow with a 1000 ml graduated cylinder Don t worry if the flow is slightly more or less than what is specified 2 Determine the appropriate concentrate flow for your system and the desired rec...

Страница 13: ...480 70 520 80 554 10 00 50 408 60 450 70 489 80 521 12 00 50 363 60 402 70 437 80 467 14 00 50 330 60 366 70 399 80 427 16 00 50 307 60 342 70 371 80 397 18 00 50 292 60 326 70 352 80 377 20 00 50 28...

Страница 14: ...or 6 000 12 000 18 000 or 24 000 gallons d Calendar scale is jumper selectable for 6 months or 12 months Monitor operation a Active green light blinks every two seconds during any minimum water flow c...

Страница 15: ...s or until the water is clear 10 Close the TO flush valve 11 Connect the 24 VAC Transformer from the 115 Volt receptacle Every 6 12 months Sanitize the storage tank 1 Refer to Start up section steps 1...

Страница 16: ...and a graduated cylinder or calibrated measuring cup The drain water flow rate can be measured from the end of the red tubing in a similar manner Inlet water flow Outlet Product Water Flow Drain Wate...

Страница 17: ...has removed 92 of the dissolved solids from the inlet water 6 The RO cartridge should be changed every 1 to 1 1 2 years or when the percent reduction falls below 90 A form has been provided below to r...

Страница 18: ...valve as required to attain specified water quality a Tubing piping run to equipment too restrictive a Increase tubing piping diameter Refer to System Installation section for recommendations 4 Low w...

Страница 19: ...19 Replacement Parts...

Страница 20: ...EV307850 Support Ring EA 2 49 EV310445 Label Carbon Filter EA 1 50 EV310446 Label RO Module EA 1 51 01010248 Adaptor 3 8 Stem X 1 4 Tube EA 1 53 EV306996 Directional Arrow EA 1 No Part Number Descrip...

Страница 21: ...hole punched Prints black ink on 50 offset white VENDOR MUST SUBMIT A MATERIAL CERTIFICATE OF COMPLIANCE WITH EACH SHIPMENT LET CHANGE BY APRVD DATE A DCO 4785 RH SK 9 12 02 B DCO 7060 KR RH 11 6 03 T...

Отзывы: