background image

 

18 

Troubleshooting Guide 

 

PROBLEM 

POSSIBLE CAUSE 

REMEDY 

a.  Pre-filter cartridge 

plugged. 

a.  Replace pre-filter cartridge. 

b.  TO cartridge plugged. 

b.  Replace TO cartridge. 

c. 

RO cartridge plugged. 

c. 

Replace RO cartridge. 

d.  Insufficient system inlet 

pressure. 

d.  Check/repair booster pump and inlet line. 

 
Add an inlet booster pump. 

1. 

Insufficient 
product water 
during normal 
operating 
periods. 

e.  Outlet water check 

valve failure. 

e.  Replace outlet water check valve. 

a.  Refer to problem 1. 

a.  Refer to problem 1. 

2. 

Insufficient 
product water 
volume during 
peak periods. 

b.  System rated output too 

low for application. 

b.  Verify system output. If output is within 

specification, increase capacity by adding a 
second system. 

a.  Refer to problem 1 

a.  Refer to problem 1. 

b.  RO cartridge failure. 

b.  Replace RO cartridge. 

3. 

Low quality RO 
water. 

c. 

Filtered water blend 
valve requires 
adjustment. 

c. 

Close filtered water blend valve as required 
to attain specified water quality. 

a   Tubing/piping run to 

equipment too 
restrictive. 

a.   Increase tubing/piping diameter. Refer to 

“System Installation” section for 
recommendations. 

4. 

Low water 
pressure at 
water using 
equipment. 

b.  Re-pressurization pump 

problem. 

b.  1.  See Problem 5. 

2.  Check/repair pump as required. 

5. 

Delivery Pump 
Cycling 
Excessively  

a.  Accumulator Tank pre-

charge pressure 
incorrect. 

a.  Check pre-charge pressure with 

accumulator tank empty on fluid side. 
Adjust to 40 PSI air pressure. 

Objectionable 
product water 
odor. 

a.  TO cartridge exhausted.  a.  Replace TO cartridge. 

a.   Drain line restricted. 

a.  Check/correct any restrictions in drain line 

tubing. Make sure to allow an air gap at the 
drain. 
 
Disconnect wastewater tubing from outlet 
quick connect fitting and inspect for dirt or 
damage to flow restrictor insert in end of 
tubing. Clean or blow out tubing/insert to 
clear. 
 
Replace wastewater tubing assembly 

7.   Wastewater 

flow too low or 
decreases 
over time. 

b.  Insufficient system inlet 

pressure. 

b.  Check/repair booster pump and inlet line. 

 
Add an inlet booster pump. 

 

Содержание MRS-200

Страница 1: ...1 Cat No EV311117 Rev B 11 6 03 DCO 7060 MODEL MRS 200 Reverse Osmosis Mineral Reduction System Installation and Start up Guide...

Страница 2: ...Installation 4 Cartridge Installation and Activation 10 Start Up and Blend Adjustment 10 Adjusting the Recovery 12 Operation 14 Maintenance 14 Performance Monitoring 16 TDS Measurement 16 Performance...

Страница 3: ...hlorine An activated carbon filter has been provided with this system to protect the reverse osmosis membrane from chlorine attack Influent chlorine should not exceed 3 mg L The MRS 200 System consist...

Страница 4: ...nd permit access for maintenance The system will weigh approximately 175 pounds when the storage tank is full 4 ____ Does the inlet water supply meet the requirements listed below 1 A minimum of 1 0 G...

Страница 5: ...nts Place the main unit on the shelf positioning the cartridge heads directly over the cutout area Insert a cable tie into one of the holes in the baseplate and through the wire slats in the shelf mak...

Страница 6: ...A MP S 2 INS E RT E LB OW FULLY 3 S LIDE LOCK ING CLIP UP TO S E CURE 1 S LIDE LOCK ING CLIP DOW N Figure 3 4 Water supplies with a dynamic operating pressure of 50 PSI or less require the use of the...

Страница 7: ...UMP 10 NUT 8 1 2 X 1 SPACER 4 10 X 1 1 2 SCREW 8 10 WASHER 16 MOUNTING PLATE Figure 4 5 Refer to Figure 5 for a sample general arrangement Use this as a guideline for determining valve location tubing...

Страница 8: ...ow control insert red plastic cylinder in small parts kit Press this insert into the red OD tubing Fig 6 Attach the end of the tubing with the flow control insert into the 3 8 stem x OD tube reducing...

Страница 9: ...lt receptacle at this time Figure 9 Figure 7 Figure 8 INLET WATER SUPPLY 50 PSIG MAX TO 120 VAC OUTLET A B C SOLENOID VALVE 1 5 2 4 3 IN A B C TO 120 VAC OUTLET SOLENOID VALVE IN COVER REMOVED 3 4 2 5...

Страница 10: ...ative solution from the RO cartridge and should not be consumed 6 If you are utilizing the capillary tubing assembly refer to the section titled Adjusting the Recovery for instructions Return to this...

Страница 11: ...to contain a range of TDS greater than what an RO system normally produces In those cases a filtered water blend valve has been provided to blend in filtered not RO treated water to attain a specific...

Страница 12: ...product flow with a 1000 ml graduated cylinder Don t worry if the flow is slightly more or less than what is specified 2 Determine the appropriate concentrate flow for your system and the desired rec...

Страница 13: ...480 70 520 80 554 10 00 50 408 60 450 70 489 80 521 12 00 50 363 60 402 70 437 80 467 14 00 50 330 60 366 70 399 80 427 16 00 50 307 60 342 70 371 80 397 18 00 50 292 60 326 70 352 80 377 20 00 50 28...

Страница 14: ...or 6 000 12 000 18 000 or 24 000 gallons d Calendar scale is jumper selectable for 6 months or 12 months Monitor operation a Active green light blinks every two seconds during any minimum water flow c...

Страница 15: ...s or until the water is clear 10 Close the TO flush valve 11 Connect the 24 VAC Transformer from the 115 Volt receptacle Every 6 12 months Sanitize the storage tank 1 Refer to Start up section steps 1...

Страница 16: ...and a graduated cylinder or calibrated measuring cup The drain water flow rate can be measured from the end of the red tubing in a similar manner Inlet water flow Outlet Product Water Flow Drain Wate...

Страница 17: ...has removed 92 of the dissolved solids from the inlet water 6 The RO cartridge should be changed every 1 to 1 1 2 years or when the percent reduction falls below 90 A form has been provided below to r...

Страница 18: ...valve as required to attain specified water quality a Tubing piping run to equipment too restrictive a Increase tubing piping diameter Refer to System Installation section for recommendations 4 Low w...

Страница 19: ...19 Replacement Parts...

Страница 20: ...EV307850 Support Ring EA 2 49 EV310445 Label Carbon Filter EA 1 50 EV310446 Label RO Module EA 1 51 01010248 Adaptor 3 8 Stem X 1 4 Tube EA 1 53 EV306996 Directional Arrow EA 1 No Part Number Descrip...

Страница 21: ...hole punched Prints black ink on 50 offset white VENDOR MUST SUBMIT A MATERIAL CERTIFICATE OF COMPLIANCE WITH EACH SHIPMENT LET CHANGE BY APRVD DATE A DCO 4785 RH SK 9 12 02 B DCO 7060 KR RH 11 6 03 T...

Отзывы: