4
ENGLISH
1.1 It is prohibited to remove the guards and safety devices
t is absolutely forbidden to remove safety guards.
The manufacturer disclaims any liability for accidents due to failure to comply with this obligation.
1.2 Information on emergency operations in the event of fire
- disconnect the Blast chiller from the power source or cut off the power supply
- do not use water jets
- use dry chemical or CO2 extinguishers
CHAPTER 2 CLEANING THE REFRIGERATOR
Since the blast chiller will be used to store food, cleaning is necessary for hygiene and health
protection purposes. The cleaning of the blast chiller has already been carried out at the factory. It
is suggested, however, to carry out an additional cleaning of the internal parts before use, making
sure that the power cord is unplugged.
2.1 Cleaning the interior and exterior cabinet
For this purpose the following are indicated
- the cleaning products: water and mild, non-abrasive detergents. DO NOT USE SOLVENTS AND
THINNERS
- methods for cleaning: wash the interior and exterior parts with warm water and mild soap or with a
cloth or sponge with suitable products
- disinfection: avoid substances that can alter the organoleptic characteristics of the food
- rinsing: cloth or sponge soaked in warm water. DO NOT USE WATER JETS
- frequency: weekly is recommended, the user can set different frequencies depending on the type
of food being stored.
REMARK:
Clean frequently the door seals.
Some preserved products could release some enzymes that could damage the seals causing its
quick deterioration. For the cleaning, use only specific products for this purposes, available also on
request on our sales network.
2.2 Cleaning the condenser
The efficiency of Blast chillers is compromised by condenser / remote condensing unit obstruction;
therefore, it is necessary to clean it monthly. Before carrying out this operation, turn off the Blast chiller
/ remote condensing unit, disconnect the power cable and proceed as follows:
Motor at the bottom
– open the front control box by unscrewing the specific screws and by turning it
on the lower hinges.
Motor at the top
- for models with non-flippable fixed front, use a safe stepladder and directly access
the condenser, placed on the upper part of the Blast chiller.
Remote condensing unit
– according to the model, remove the condenser protection as per instructions
on the supplied unit manual.
Remove dust and lint from the wings by vertical movements with the help of an air jet or a dry brush.
In case of oily deposits, use a brush imbibed with specific detergents. For models with flippable fronts,
unscrew the block screw and turn the front by the top hinges; proceed then with cleaning as for models
with fixed front. After completing the operation, restart the Blast chiller. Evaporators installed above
the appliances are cartaphoresis-treated to reduce corrosion problems.