14
2. Wipe off the silicone sealing bar gasket on
the bell-lid (Fig 8.2) every day with a damp
cloth and mild detergent.
(Fig 8.2)
Silicone Sealing Bar Gasket on the
bell-lid
3. Replacement of the Silicon Sealing Bar
Gasket on the Bell-Lid (Fig 8.2).
Inspect the silicone sealing bar gasket for
wear. If it is worn, it will cause the clear
chamber bell-lid to pop open on its own,
affecting the vacuum sealing of the product
and it must be replaced. To replace it, pull it
from the gasket retainer and make sure the
retainer is clean of debris. Install the new one
by pressing in place. Close lid and test for a
seal.
4.
Replacement of the Clear Chamber
Bell-Lid Gasket.
5.
Replacement of Teflon Sealing Bar
The sealing bar needs to be replaced by a
qualified service technician.
Image 8.3
. Sealing bar teflon
The silicone gaskets and the Teflon
sealing bar should be replaced every 200
working hours, for maximum efficiency.
The check of pump, filters and electro
valves must be done every 2000 working
hours by authorized personnel only
(Fig 8.3)
Clear Chamber Bell-Lid Gasket
Remove the gasket by carefully pulling out the
gasket from the clear chamber bell-lid groove.
Ensure the gasket groove is clean and free of
debris and press a new one in place. Close lid
and test for a seal.
Содержание PrepRite PVS27-6-1
Страница 16: ...16 CHAPTER 10 NAME PLATE AND TECHNICAL DETAILS CONFIGURATION AND CONSUMPTION Image 8 5 Name plate example...
Страница 17: ...17 CHAPTER 11...
Страница 18: ...18 EXPLODED VIEWS AND PART...
Страница 19: ...19 LISTS...
Страница 20: ...20...
Страница 21: ...21...
Страница 22: ...22...
Страница 23: ...23...
Страница 24: ...24 CHAPTER 12 WIRING DIAGRAMS PVS27 PVS32 PVS32G PVS42 PVS42BG PVS5225 PVS52G...
Страница 25: ...25...
Страница 26: ...26...