12
pause, until the time set has elapsed. When set
to
0
, the pump will run continuously for the
time set.
Vacuum Type 0: standard vacuum.
Vacuum Type 1: soft vacuum with
intermittent pump activated.
By pressing the
SET
button it will confirm
the selection and move to the next option.
2. Sealing Time Setting
By pressing the
SET
button, the following
will appear:
By using the
+ or
–
buttons it is possible to
increase or decrease the time of sealing
(tenths of seconds, between 0 and 4
seconds).
By pressing the
SET
button it will confirm
the selection and move to the next option.
3. Gas flush setting
(GAS OPTION)
By pressing the SET button, the following
will appear:
By using the
+
or
–
buttons it is possible to
increase or decrease the time of gas
injection (tenths of seconds, between 0 and
9.9 seconds).
By pressing the button
SET
it will confirm
the selection and move to the next option.
Do not set time of gas flush longer than
vacuum time, otherwise the lid open
prematurely.
Make sure that the gas pressure
entering the chamber is not higher
than 14 -21 PSI or (1
–
1.5 bars)
4. Printer Label Settings
(PRINTER OPTION)
By pressing the
SET
button, the following
will appear:
By using the buttons
+ or
–
it is possible to
set the first number, indicating the number
of product labels to be printed (between 1
and 9).
NOTE:
Setting this number to 0, will
cause the printer to not print any labels.
By pressing the
SET
button the cursor will
move to the second number, indicating the
number of days the product can be held
(between 1 and 183). By pressing the
SET
button it will confirm the selection and move
to the next option.
5. Product Name and Ingredients
Setting.
By pressing the SET button, there will be an
empty line on the display:
By using the
+
or
-
buttons, it is possible
to insert a text of up to 16 lines with 16
characters each allowing the printing on
the labels (i.e. food name, ingredients…)
.
If there are no further options, the display
will show the number of the program
modified. This means that all parameters
are properly set.
7.2 MANUAL SEALING
While running a normal processing cycle, push
and hold the
PUMP GASTRO
for 3 seconds you
can start the sealing process before the end of
the cycle.
Sealing
2.0
2.0
Gas
0.0
Stamp
3/ 1
Содержание PrepRite PVS27-6-1
Страница 16: ...16 CHAPTER 10 NAME PLATE AND TECHNICAL DETAILS CONFIGURATION AND CONSUMPTION Image 8 5 Name plate example...
Страница 17: ...17 CHAPTER 11...
Страница 18: ...18 EXPLODED VIEWS AND PART...
Страница 19: ...19 LISTS...
Страница 20: ...20...
Страница 21: ...21...
Страница 22: ...22...
Страница 23: ...23...
Страница 24: ...24 CHAPTER 12 WIRING DIAGRAMS PVS27 PVS32 PVS32G PVS42 PVS42BG PVS5225 PVS52G...
Страница 25: ...25...
Страница 26: ...26...